Literature DB >> 20174107

Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging.

Sergio Ortiz1, Damian Siedlecki, Ireneusz Grulkowski, Laura Remon, Daniel Pascual, Maciej Wojtkowski, Susana Marcos.   

Abstract

A method for three-dimensional 3-D optical distortion (refraction) correction on anterior segment Optical Coherence Tomography (OCT) images has been developed. The method consists of 3-D ray tracing through the different surfaces, following denoising, segmentation of the surfaces, Delaunay representation of the surfaces, and application of fan distortion correction. The correction has been applied theoretically to realistic computer eye models, and experimentally to OCT images of: an artificial eye with a Polymethyl Methacrylate (PMMA) cornea and an intraocular lens (IOL), an enucleated porcine eye, and a human eye in vivo obtained from two OCT laboratory set-ups (time domain and spectral). Data are analyzed in terms of surface radii of curvature and asphericity. Comparisons are established between the reference values for the surfaces (nominal values in the computer model; non-contact profilometric measurements for the artificial eye; Scheimpflug imaging for the real eyes in vivo and vitro). The results from the OCT data were analyzed following the conventional approach of dividing the optical path by the refractive index, after application of 2-D optical correction, and 3-D optical correction (in all cases after fan distortion correction). The application of 3-D optical distortion correction increased significantly both the accuracy of the radius of curvature estimates and particularly asphericity of the surfaces, with respect to conventional methods of OCT image analysis. We found that the discrepancies of the radii of curvature estimates from 3-D optical distortion corrected OCT images are less than 1% with respect to nominal values. Optical distortion correction in 3-D is critical for quantitative analysis of OCT anterior segment imaging, and allows accurate topography of the internal surfaces of the eye.

Entities:  

Mesh:

Year:  2010        PMID: 20174107     DOI: 10.1364/OE.18.002782

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  48 in total

1.  OCT-based crystalline lens topography in accommodating eyes.

Authors:  Pablo Pérez-Merino; Miriam Velasco-Ocana; Eduardo Martinez-Enriquez; Susana Marcos
Journal:  Biomed Opt Express       Date:  2015-11-24       Impact factor: 3.732

2.  Correction of image distortions in endoscopic optical coherence tomography based on two-axis scanning MEMS mirrors.

Authors:  Donglin Wang; Peng Liang; Sean Samuelson; Hongzhi Jia; Junshan Ma; Huikai Xie
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

3.  Extended scan depth optical coherence tomography for evaluating ocular surface shape.

Authors:  Meixiao Shen; Lele Cui; Ming Li; Dexi Zhu; Michael R Wang; Jianhua Wang
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

4.  Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.

Authors:  Ryan P McNabb; James Polans; Brenton Keller; Moseph Jackson-Atogi; Charlene L James; Robin R Vann; Joseph A Izatt; Anthony N Kuo
Journal:  Biomed Opt Express       Date:  2018-12-21       Impact factor: 3.732

5.  System for on- and off-axis volumetric OCT imaging and ray tracing aberrometry of the crystalline lens.

Authors:  Marco Ruggeri; Siobhan Williams; Bianca Maceo Heilman; Yue Yao; Yu-Cherng Chang; Ashik Mohamed; N Geetha Sravani; Heather Durkee; Cornelis Rowaan; Alex Gonzalez; Arthur Ho; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

6.  Topography and pachymetry maps for mouse corneas using optical coherence tomography.

Authors:  Alice S Liu; Dillon M Brown; Rachel E Conn; Ryan P McNabb; Machelle T Pardue; Anthony N Kuo
Journal:  Exp Eye Res       Date:  2019-11-05       Impact factor: 3.467

7.  Brillouin microscopy of collagen crosslinking: noncontact depth-dependent analysis of corneal elastic modulus.

Authors:  Giuliano Scarcelli; Sabine Kling; Elena Quijano; Roberto Pineda; Susana Marcos; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-02-19       Impact factor: 4.799

8.  Multi-meridian corneal imaging of air-puff induced deformation for improved detection of biomechanical abnormalities.

Authors:  Andrea Curatolo; Judith S Birkenfeld; Eduardo Martinez-Enriquez; James A Germann; Geethika Muralidharan; Jesús Palací; Daniel Pascual; Ashkan Eliasy; Ahmed Abass; Jędrzej Solarski; Karol Karnowski; Maciej Wojtkowski; Ahmed Elsheikh; Susana Marcos
Journal:  Biomed Opt Express       Date:  2020-10-14       Impact factor: 3.732

9.  Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography.

Authors:  Pablo Eugui; Danielle J Harper; Stefan Kummer; Antonia Lichtenegger; Johanna Gesperger; Tanja Himmel; Marco Augustin; Conrad W Merkle; Martin Glösmann; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2020-03-19       Impact factor: 3.732

10.  A Mosaicking Approach for In Vivo Thickness Mapping of the Human Tympanic Membrane Using Low Coherence Interferometry.

Authors:  Paritosh Pande; Ryan L Shelton; Guillermo L Monroy; Ryan M Nolan; Stephen A Boppart
Journal:  J Assoc Res Otolaryngol       Date:  2016-07-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.