Literature DB >> 20172817

Spatio-temporal data fusion for 3D+T image reconstruction in cerebral angiography.

Andrew D Copeland1, Rami S Mangoubi, Mukund N Desai, Sanjoy K Mitter, Adel M Malek.   

Abstract

This paper provides a framework for generating high resolution time sequences of 3D images that show the dynamics of cerebral blood flow. These sequences have the potential to allow image feedback during medical procedures that facilitate the detection and observation of pathological abnormalities such as stenoses, aneurysms, and blood clots. The 3D time series is constructed by fusing a single static 3D model with two time sequences of 2D projections of the same imaged region. The fusion process utilizes a variational approach that constrains the volumes to have both smoothly varying regions separated by edges and sparse regions of nonzero support. The variational problem is solved using a modified version of the Gauss-Seidel algorithm that exploits the spatio-temporal structure of the angiography problem. The 3D time series results are visualized using time series of isosurfaces, synthetic X-rays from arbitrary perspectives or poses, and 3D surfaces that show arrival times of the contrasted blood front using color coding. The derived visualizations provide physicians with a previously unavailable wealth of information that can lead to safer procedures, including quicker localization of flow altering abnormalities such as blood clots, and lower procedural X-ray exposure. Quantitative SNR and other performance analysis of the algorithm on computational phantom data are also presented.

Entities:  

Mesh:

Year:  2010        PMID: 20172817     DOI: 10.1109/TMI.2009.2039645

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Optimizing the Quality of 4D-DSA Temporal Information.

Authors:  K L Ruedinger; E C Harvey; S Schafer; M A Speidel; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-31       Impact factor: 3.825

2.  3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms.

Authors:  Uroš Mitrović; Boštjan Likar; Franjo Pernuš; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-10-24       Impact factor: 2.924

Review 3.  4D-DSA: Development and Current Neurovascular Applications.

Authors:  K L Ruedinger; S Schafer; M A Speidel; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2020-11-26       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.