Literature DB >> 20172592

Performance of UV disinfection and the microbial quality of greywater effluent along a reuse system for toilet flushing.

Eran Friedler1, Yael Gilboa.   

Abstract

This paper examines the microbial quality of treated RBC (Rotating Biological Contactor) and MBR (Membrane Bioreactor) light greywater along a continuous pilot-scale reuse system for toilet flushing, quantifies the efficiency of UV disinfection unit, and evaluates the regrowth potential of selected microorganisms along the system. The UV disinfection unit was found to be very efficient in reducing faecal coliforms and Staphylococcus aureus. On the other hand, its efficiency of inactivation of HPC (Heterotrophic Plate Count) and Pseudomonas aeruginosa was lower. Some regrowth occurred in the reuse system as a result of HPC regrowth which included opportunistic pathogens such as P. aeruginosa. Although the membrane (UF) of the MBR system removed all bacteria from the greywater, bacteria were observed in the reuse system due to "hopping phenomenon." The microbial quality of the disinfected greywater was found to be equal or even better than the microbial quality of "clean" water in toilet bowls flushed with potable water (and used for excretion). Thus, the added health risk associated with reusing the UV-disinfected greywater for toilet flushing (regarding P. aeruginosa and S. aureus), was found to be insignificant. The UV disinfection unit totally removed (100%) the viral indicator (F-RNA phage, host: E. coli F(amp)(+)) injected to the treatment systems simulating transient viral contamination. To conclude, this work contributes to better design of UV disinfection reactors and provides an insight into the long-term behavior of selected microorganisms along on-site greywater reuse systems for toilet flushing. (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20172592     DOI: 10.1016/j.scitotenv.2010.01.051

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  8 in total

1.  Modeling and kinetic characterization of wastewater disinfection using chlorine and UV irradiation.

Authors:  Brahmi Mounaouer; Hassen Abdennaceur
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-16       Impact factor: 4.223

Review 2.  Constructed wetlands for greywater recycle and reuse: A review.

Authors:  S Arden; X Ma
Journal:  Sci Total Environ       Date:  2018-02-26       Impact factor: 7.963

3.  Removal of organic micropollutants from biologically treated greywater using continuous-flow vacuum-UV/UVC photo-reactor.

Authors:  Yael Dubowski; Yuval Alfiya; Yael Gilboa; Sara Sabach; Eran Friedler
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-29       Impact factor: 4.223

4.  Lumiestrone is Photochemically Derived from Estrone and may be Released to the Environment without Detection.

Authors:  Vance L Trudeau; Belinda Heyne; Jules M Blais; Fabio Temussi; Susanna K Atkinson; Farzad Pakdel; Jason T Popesku; Vicki L Marlatt; Juan C Scaiano; Lucio Previtera; David R S Lean
Journal:  Front Endocrinol (Lausanne)       Date:  2011-12-02       Impact factor: 5.555

5.  Total staphylococci as performance surrogate for greywater treatment.

Authors:  David C Shoults; Nicholas J Ashbolt
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-01       Impact factor: 4.223

6.  Enhanced visible-light photodegradation of fluoroquinolone-based antibiotics and E. coli growth inhibition using Ag-TiO2 nanoparticles.

Authors:  Jiao Wang; Ladislav Svoboda; Zuzana Němečková; Massimo Sgarzi; Jiří Henych; Nadia Licciardello; Gianaurelio Cuniberti
Journal:  RSC Adv       Date:  2021-04-13       Impact factor: 3.361

7.  H2S Removal from Groundwater by Chemical Free Advanced Oxidation Process Using UV-C/VUV Radiation.

Authors:  Yael Gilboa; Yuval Alfiya; Sara Sabach; Eran Friedler; Yael Dubowski
Journal:  Molecules       Date:  2021-06-30       Impact factor: 4.411

8.  Microbiological Health Risk Assessment of Water Conservation Strategies: A Case Study in Amsterdam.

Authors:  Agung Kusumawardhana; Ljiljana Zlatanovic; Arne Bosch; Jan Peter van der Hoek
Journal:  Int J Environ Res Public Health       Date:  2021-03-05       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.