Literature DB >> 20171941

Simple liquid chromatography method for the quantification of irinotecan and SN38 in sheep plasma: application to in vivo pharmacokinetics after pulmonary artery chemoembolization using drug eluting beads.

Minh-Tâm Baylatry1, Anne-Christine Joly, Jean-Pierre Pelage, Leila Bengrine-Lefevre, Jean-Louis Prugnaud, Alex Laurent, Christine Fernandez.   

Abstract

A rapid and simple liquid chromatography-fluorescence detection (LC-FD) method was developed and validated for the simultaneous quantification of irinotecan (CPT11) and SN38 in sheep plasma. Camptothecin (CPT) was used as the internal standard. A single step protein precipitation with acetonitrile was used for sample preparation. The separation was achieved using a 5 microm C18 column (250 mm x 4.5 mm, 5 microm) with a mobile phase composed of 36 mM sodium dihydrogen phosphate dehydrate and 4 mM sodium 1 heptane sulfonate-acetonitrile (72:28), the pH of the mobile phase was adjusted to 3. The flow rate was 1.45 mL/min and the fluorescence detection was operated at 355/515 nm (excitation/emission wavelengths). The run time was 13 min. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision and accuracy, limit of quantification and stability. The method has a limit of quantification of 5 ng/mL for both CPT11 and SN38. The assay was linear over concentrations ranging from 5 to 5000 ng/mL and to 240 ng/mL for CPT11 and SN38, respectively. This method was used successfully to perform plasma pharmacokinetic studies of CPT11 after pulmonary artery embolization (PACE) in a sheep model. It was also validated for CPT11 and SN38 analysis in sheep lymph and human plasma. 2010. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20171941     DOI: 10.1016/j.jchromb.2010.01.017

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Quantification of irinotecan, SN38, and SN38G in human and porcine plasma by ultra high-performance liquid chromatography-tandem mass spectrometry and its application to hepatic chemoembolization.

Authors:  Xiaohong Chen; Cody J Peer; Raul Alfaro; Tian Tian; Shawn D Spencer; William D Figg
Journal:  J Pharm Biomed Anal       Date:  2012-01-16       Impact factor: 3.935

2.  Drug penetration and metabolism in 3D cell cultures treated in a 3D printed fluidic device: assessment of irinotecan via MALDI imaging mass spectrometry.

Authors:  Gabriel J LaBonia; Sarah Y Lockwood; Andrew A Heller; Dana M Spence; Amanda B Hummon
Journal:  Proteomics       Date:  2016-06       Impact factor: 3.984

3.  Evaluation of therapeutics in three-dimensional cell culture systems by MALDI imaging mass spectrometry.

Authors:  Xin Liu; Eric M Weaver; Amanda B Hummon
Journal:  Anal Chem       Date:  2013-06-11       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.