Literature DB >> 20170877

Serial angiography and intravascular ultrasound: results of the SISC Registry (Stents In Small Coronaries).

Daniel Chamié1, J Ribamar Costa, Alexandre Abizaid, Fausto Feres, Rodolfo Staico, Fernando Devito, Ricardo A Costa, Andréa Abizaid, Luiz Fernando Tanajura, Amanda G M R Sousa, Peter J Fitzgerald, Robert J Whitbourn, J Eduardo Sousa.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the novel CardioMind Sparrow (CMS) stent (CardioMind, Inc., Sunnyvale, California) against the Multi-Link Pixel (MLP) stent (Guidant Corp., Santa Clara, California) for small vessel percutaneous coronary intervention (PCI).
BACKGROUND: The CMS consists of a guidewire-based, self-expandable, ultra-thin nitinol stent with smaller profile and improved flexibility and deliverability. The performance of this novel device against a standard balloon-expandable stent for small vessel PCI has not been determined.
METHODS: Twenty-one patients were treated with the CMS and compared with 30 patients treated with MLP. Only single de novo lesions <14 mm in length, in native vessels of 2.0 to 2.5 mm were included. The primary goal was the comparison of quantitative coronary angiography lumen loss and intravascular ultrasound intimal hyperplasia (IH) formation between groups at 6 months.
RESULTS: Clinical characteristics were similar between groups. The CMS cohort had smaller vessels (2.20 +/- 0.20 mm vs. 2.43 +/- 0.16 mm, p < 0.0001) and shorter lesions (10.86 +/- 3.19 mm vs. 13.12 +/- 2.79 mm, p = 0.0091). Six-month late loss was significantly lower among CMS cohort (0.73 +/- 0.57 mm vs. 1.11 +/- 0.72 mm, p = 0.038). By intravascular ultrasound, 6-month IH volume was similar between groups (1.45 +/- 0.46 mm(3)/mm vs. 1.65 +/- 1.02 mm(3)/mm, p = 0.50). However, CMS presented a mean 13.39% expansion of its volumes, resulting in a significantly lower percentage of IH volumetric obstruction (31.94 +/- 8.19% vs. 39.90 +/- 4.72%, p = 0.0005).
CONCLUSIONS: Despite producing similar amounts of IH volume, the self-expanding CMS stent presented chronic expansion of its volumes, better accommodating the neoformed tissue and resulting in significantly lower late loss and percent of IH volumetric obstruction in comparison with the MLP stent. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20170877     DOI: 10.1016/j.jcin.2009.11.014

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  2 in total

Review 1.  New concepts in the design of drug-eluting coronary stents.

Authors:  Scot Garg; Christos Bourantas; Patrick W Serruys
Journal:  Nat Rev Cardiol       Date:  2013-02-19       Impact factor: 32.419

2.  An agent-based model of the response to angioplasty and bare-metal stent deployment in an atherosclerotic blood vessel.

Authors:  Antonia E Curtin; Leming Zhou
Journal:  PLoS One       Date:  2014-04-14       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.