Literature DB >> 2017025

Within-cycle characteristics of the wheelchair push in sprinting on a wheelchair ergometer.

H E Veeger1, L H van der Woude, R H Rozendal.   

Abstract

To investigate power output and torque production in wheelchair sprinting, six able-bodied subjects performed nine 20-s sprint tests on a stationary wheelchair ergometer (load 0-8 kg). Ergometer data were analyzed and combined with kinematic data and surface electromyography. Of all power and torque parameters investigated, only maximal power output was independent of load (mean peak value 375 W, one-sided). Mean power output is suggested to be a useful indicator for anaerobic power production, but test conditions concerned speed in relation to handrim diameter should be specified. The relevance of the "mechanical constraint principle" for handrim propulsion is discussed. Within one cycle, power and torque curves showed a negative deflection at the beginning and a valley approximately halfway through the push phase. The relation of these phenomena to kinematic parameters and muscle activity is discussed.

Mesh:

Year:  1991        PMID: 2017025

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  7 in total

Review 1.  Physiology of wheelchair racing in athletes with spinal cord injury.

Authors:  Yagesh Bhambhani
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

Review 2.  Wheelchair propulsion biomechanics: implications for wheelchair sports.

Authors:  Y Vanlandewijck; D Theisen; D Daly
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

3.  Differences in performance between trained and untrained subjects during a 30-s sprint test in a wheelchair ergometer.

Authors:  H E Veeger; E M Lute; K Roeleveld; L H van der Woude
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

Review 4.  Anaerobic fitness testing of wheelchair users.

Authors:  Y Hutzler
Journal:  Sports Med       Date:  1998-02       Impact factor: 11.136

5.  Design and Fabrication of an Instrumented Handrim to Measure the Kinetic and Kinematic Information by the Hand of User for 3D Analysis of Manual Wheelchair Propulsion Dynamics.

Authors:  Mohammadreza Mallakzadeh; Hossein Akbari
Journal:  J Med Signals Sens       Date:  2014-10

6.  Evaluation of a standardized test protocol to measure wheelchair-specific anaerobic and aerobic exercise capacity in healthy novices on an instrumented roller ergometer.

Authors:  Rowie J F Janssen; Riemer J K Vegter; Han Houdijk; Lucas H V Van der Woude; Sonja de Groot
Journal:  PLoS One       Date:  2022-09-06       Impact factor: 3.752

7.  Predicting manual wheelchair initiation movement with EMG activity during over ground propulsion.

Authors:  Soufien Chikh; Samuel Boudet; Antonio Pinti; Cyril Garnier; Rawad El Hage; Fairouz Azaiez; Eric Watelain
Journal:  J Spinal Cord Med       Date:  2020-07-09       Impact factor: 1.985

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.