| Literature DB >> 20165398 |
H W Icenogle, B C Platt, W L Wolfe.
Abstract
The refractive indexes and their variations with temperature for silicon and germanium have been measured over the 95-298-K and 2.5-12-microm ranges. Data are given for the refractive index that are in reasonable agreement with those of previous investigators. For dn/dT the values are independent of wavelength and are approximately 1.5 x 10(-4) (K)(-1) and 4.0 x 10(-4) (K)(-1) for silicon and germanium, respectively.Entities:
Year: 1976 PMID: 20165398 DOI: 10.1364/AO.15.002348
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980