Literature DB >> 2016447

Comparison of technetium-99m teboroxime tomography with automated quantitative coronary arteriography and thallium-201 tomographic imaging.

R M Fleming1, R L Kirkeeide, H Taegtmeyer, A Adyanthaya, D B Cassidy, R A Goldstein.   

Abstract

Technetium-99m (Tc-99m) teboroxime is a new perfusion tracer that is highly extracted and rapidly cleared by the myocardium. To determine the feasibility of Tc-99m teboroxime imaging in the diagnosis of patients with suspected coronary artery disease, 30 patients underwent single photon emission computed tomography imaging with Tc-99m teboroxime (25.2 +/- 1 mCi) at peak exercise and again 60 min later at rest. All patients underwent either a thallium stress test (n = 26) or automated quantitative coronary arteriography (n = 25), or both, without intervening revascularization or infarction. Images were reviewed by two investigators who had no knowledge of clinical data. Coronary lesions with greater than or equal to 50% diameter narrowing by quantitative coronary arteriography were considered significant. Both thallium and Tc-99m teboroxime detected disease in all patients with two or three vessel disease. One vessel disease was detected with Tc-99m teboroxime in 9 of 10 patients and with thallium in 8 of 10 (p = NS). In patients without angiographically significant disease. Tc-99m teboroxime demonstrated normal perfusion in six of eight patients and thallium in three of five (p = NS). Overall, when presence or absence of disease detected by Tc-99m teboroxime or thallium was compared with quantitative coronary arteriography, there was no difference between Tc-99m teboroxime and thallium. These results suggest that Tc-99m teboroxime is comparable to thallium as an imaging agent. The rapid biologic half-life, 5.3 min, allows studies to be completed in 60 to 90 min.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2016447     DOI: 10.1016/s0735-1097(10)80139-1

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  6 in total

1.  Anatomy of a meta-analysis: a critical review of "exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance".

Authors:  S M Kymes; D E Bruns; L J Shaw; K N Gillespie; J W Fletcher
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

2.  FMTVDM-TFM©℗: True quantification requires standardization of the tool being used to measure, with a known, unchanging standard to produce accurate, consistent and reproducible quantified measurements.

Authors:  Richard M Fleming; Matthew R Fleming; Andrew McKusick; Tapan Chaudhuri
Journal:  J Nucl Cardiol       Date:  2018-06-19       Impact factor: 5.952

3.  Myocardial technetium 99m-labeled teboroxime clearance derived from canine scans differentiates severity of stenosis after dipyridamole.

Authors:  G Johnson; D K Glover; C B Hebert; R D Okada
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

4.  The Canadian exercise technetium 99m-labeled teboroxime single-photon emission computed tomographic study. Canadian Exercise Teboroxime SPECT Study Investigators.

Authors:  R J Burns; S Iles; A Y Fung; L M Wright; L Daigneault
Journal:  J Nucl Cardiol       Date:  1995 Mar-Apr       Impact factor: 5.952

Review 5.  Technetium-labeled myocardial imaging agents.

Authors:  A S Iskandrian; J Heo
Journal:  Int J Card Imaging       Date:  1992

6.  Effect of co-ligands on chemical and biological properties of (99m)Tc(III) complexes [(99m)Tc(L)(CDO)(CDOH)2BMe] (L=Cl, F, SCN and N3; CDOH2=cyclohexanedione dioxime).

Authors:  Yumin Zheng; Shundong Ji; Elena Tomaselli; Carley Ernest; Tom Freiji; Shuang Liu
Journal:  Nucl Med Biol       Date:  2014-08-01       Impact factor: 2.408

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.