Mechanical stability of immediately loaded implants with various surfaces and designs: a pilot study in dogs.

Jörg Neugebauer1, Michael Weinländer, Vojislav Lekovic, Karl-Heinz Linne von Berg, Joachim E Zoeller.   

Abstract

PURPOSE: Immediate loading is among the most innovative techniques in implant therapy today. This pilot study investigates the biomechanical outcome of various designs and surfaces that claim to shorten implant treatment.
MATERIALS AND METHODS: In each quadrant of two mongrel dogs, four different implants were used for immediate loading. The following implants were placed 3 months after tooth extraction: screw with low thread profile and anodic oxidized surface (LPAOS), solid screw with wide thread profile and titanium plasma spray coating (WPTPS), screw with low profile and hybrid design of double-etched and machined surface (LPHES), and screw with two thread profiles and a sandblasted and acid-etched surface (DTSAE). The insertion torque of each implant was above 35 Ncm. Resonance frequency analysis was performed after implant placement and again after sacrifice. Additionally, the removal torque and the amount of embedded titanium particles in the peri-implant bone were measured.
RESULTS: All 16 prostheses were functional after a 5-month loading period. The highest mean removal torque values were recorded with WPTPS implants (24.4 Ncm/mm), followed by DTSAE implants (22.3 Ncm/mm) and LPAOS implants (18.7 Ncm/mm); the lowest score was obtained by LPHES (12.0 Ncm/mm). The ISQ values increased between the time of surgery and recall for all systems on average, but a significant positive correlation was found for DTSAE only. Significantly higher amounts of titanium were found in the surrounding bone with WPTPS (0.76%) and LPAOS (0.41%) in comparison with DTSAE (0.10%) and LPHES (0.03%).
CONCLUSION: Immediate loading is possible with various designs and surfaces if high primary stability can be achieved during implant placement.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20162113

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  2 in total

Review 1.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

2.  The effect of implant length and diameter on the primary stability in different bone types.

Authors:  Hamidreza Barikani; Shadab Rashtak; Soolmaz Akbari; Samareh Badri; Niloufar Daneshparvar; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2013-09-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.