Stress analysis in simulation models with or without implant threads representation.

Wirley Gonçalves Assunção1, Erica Alves Gomes, Valentim Adelino Ricardo Barão, Edson Antonio Capello de Sousa.   

Abstract

PURPOSE: This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis.
MATERIALS AND METHODS: Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models. The Von Mises stresses were measured.
RESULTS: The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex.
CONCLUSIONS: Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20162107

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  A Novel Rat Model of Orthodontic Tooth Movement Using Temporary Skeletal Anchorage Devices: 3D Finite Element Analysis and In Vivo Validation.

Authors:  Neelambar Kaipatur; Yuchin Wu; Samer Adeeb; Thomas Stevenson; Paul Major; Michael Doschak
Journal:  Int J Dent       Date:  2014-09-10

2.  Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis.

Authors:  Mansi Manish Oswal; Ulhas N Amasi; Manish S Oswal; Ashish S Bhagat
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

3.  Comparison of the Effect of Three Abutment-implant Connections on Stress Distribution at the Internal Surface of Dental Implants: A Finite Element Analysis.

Authors:  Saeed Raoofi; Maryam Khademi; Reza Amid; Mahdi Kadkhodazadeh; Mohammad Reza Movahhedi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-08-30

4.  FEA model analysis of the effects of the stress distribution of saddle-type implants on the alveolar bone and the structural/physical stability of implants.

Authors:  Yoon Soo Kong; Jun Woo Park; Dong Ju Choi
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-02-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.