Literature DB >> 2016140

Histopathology of continuous wave neodymium: yttrium aluminum garnet and diode laser contact transscleral lesions in rabbit ciliary body. A comparative study.

R Brancato1, G Leoni, G Trabucchi, A Cappellini.   

Abstract

Neodymium: yttrium aluminum garnet (Nd:YAG) laser transscleral cyclophotocoagulation has been shown to be an effective method of lowering intraocular pressure (IOP). Transmission and absorption features of diode laser radiation (810 nm) make these new laser sources suitable for production of transscleral thermal lesions. The transscleral effects on rabbit ciliary body of Nd:YAG and diode laser wavelengths were compared using a CW Nd:YAG laser and a CW Aluminum Gallium Arsenide diode laser. Both lasers were delivered by silica optic fibers, 600 microns in diameter. Eight rabbits were treated by applying the optic fiber 0.5 mm from limbus while increasing energy values from 0.2-2 J. The lesions produced at equal energy values underwent gross and histologic and ultrastructural comparison. Gross examination revealed threshold lesions at 1 J energy for the Nd:YAG laser and 0.8 J for the diode laser. The diode laser produced transscleral thermal lesions of the rabbit ciliary body comparable to those achieved by the Nd:YAG laser. The histologic and ultrastructural study showed that diode laser radiation produced more remarkable damage to the ciliary pigmented structures, causing deep coagulation necrosis of the pigmented epithelium, wide disorganization of the collagen in the stroma, and intravascular coagulation phenomena in the ciliary vessels. Before the introduction of these new laser sources in clinical transscleral procedures, further investigation is needed to determine optimal energy levels.

Entities:  

Mesh:

Year:  1991        PMID: 2016140

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  12 in total

1.  Long term results of diode laser cycloablation in complex glaucoma using the Zeiss Visulas II system.

Authors:  S Ataullah; S Biswas; P H Artes; E O'Donoghue; A E A Ridgway; A F Spencer
Journal:  Br J Ophthalmol       Date:  2002-01       Impact factor: 4.638

2.  Initial experience with a new method of laser transscleral cyclophotocoagulation for ciliary ablation in severe glaucoma.

Authors:  D E Gaasterland; I P Pollack
Journal:  Trans Am Ophthalmol Soc       Date:  1992

3.  Pathology of cyclodiode laser: a series of nine enucleated eyes.

Authors:  P A McKelvie; M J Walland
Journal:  Br J Ophthalmol       Date:  2002-04       Impact factor: 4.638

4.  Microwave cyclodestruction: evaluation on human eyes.

Authors:  P T Finger; H D Perry; J L Shakin; D R Bisciotti; R J Nattis
Journal:  Br J Ophthalmol       Date:  1995-07       Impact factor: 4.638

5.  "Cyclodiode": results of a standard protocol.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1999-03       Impact factor: 4.638

6.  Controlled Cyclophotocoagulation with diode laser in refractory glaucoma and long term follow up at King Abdulaziz University Hospital, Riyadh.

Authors:  Essam A Osman; Abdulrahman Al-Muammar; Ahmed Mousa; Hani Al-Mezaine; Saleh A Al-Obeidan
Journal:  Saudi J Ophthalmol       Date:  2010-01-07

7.  Vascular effects on ciliary tissue from endoscopic versus trans-scleral cyclophotocoagulation.

Authors:  S C Lin; M J Chen; M S Lin; E Howes; R L Stamper
Journal:  Br J Ophthalmol       Date:  2006-04       Impact factor: 4.638

8.  Trans-scleral diode laser cyclophotocoagulation for refractory glaucoma after high-risk penetrating keratoplasty.

Authors:  Alejandro Rodríguez-García; Luis Alonso González-González; J Carlos Alvarez-Guzmán
Journal:  Int Ophthalmol       Date:  2015-09-29       Impact factor: 2.031

9.  The location of sites and effect of semiconductor diode trans-scleral cyclophotocoagulation on the buphthalmic equine globe.

Authors:  Anne J Gemensky-Metzler; David A Wilkie; Steven E Weisbrode; Sonia E Kuhn
Journal:  Vet Ophthalmol       Date:  2014-04-03       Impact factor: 1.644

10.  A comparison between tube surgery, ND:YAG laser and diode laser cyclophotocoagulation in the management of refractory glaucoma.

Authors:  Philip A Bloom; Colin I Clement; Anthony King; Baha Noureddin; Kamal Sharma; Roger A Hitchings; Peng T Khaw
Journal:  Biomed Res Int       Date:  2013-10-07       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.