Literature DB >> 20160907

An Ion Mobility-Mass Spectrometry Investigation of Monocyte Chemoattractant Protein-1.

Matthew R Schenauer1, Julie A Leary.   

Abstract

In the present article we describe the gas-phase dissociation behavior of the dimeric form of monocyte chemoattractant protein-1 (MCP-1) using quadrupole-traveling wave ion mobility-time of flight mass spectrometry (q-TWIMS-TOF MS) (Waters Synapt™). Through investigation of the 9(+) charge state of the dimer, we were able to monitor dissociation product ion (monomer) formation as a function of activation energy. Using ion mobility, we were able to observe precursor ion structural changes occurring throughout the activation process. Arrival time distributions (ATDs) for the 5(+) monomeric MCP-1 product ions, derived from the gas-phase dissociation of the 9(+) dimer, were then compared with ATDs obtained for the 5(+) MCP-1 monomer isolated directly from solution. The results show that the dissociated monomer is as compact as the monomer arising from solution, regardless of the trap collision energy (CE) used in the dissociation. The solution-derived monomer, when collisionally activated, also resists significant unfolding within measure. Finally, we compared the collisional activation data for the MCP-1 dimer with an MCP-1 dimer non-covalently bound to a single molecule of the semi-synthetic glycosaminoglycan (GAG) analog Arixtra™; the latter a therapeutic anti-thrombin III-activating pentasaccharide. We observed that while dimeric MCP-1 dissociated at relatively low trap CEs, the Arixtra-bound dimer required much higher energies, which also induced covalent bond cleavage in the bound Arixtra molecule. Both the free and Arixtra-bound dimers became less compact and exhibited longer arrival times with increasing trap CEs, albeit the Arixtra-bound complex at slightly higher energies. That both dimers shifted to longer arrival times with increasing activation energy, while the dissociated MCP-1 monomers remained compact, suggests that the longer arrival times of the Arixtra-free and Arixtra-bound dimers may represent a partial breach of non-covalent interactions between the associated MCP-1 monomers, rather than extensive unfolding of individual subunits. The fact that Arixtra preferentially binds MCP-1 dimers and prevents dimer dissociation at comparable activation energies to the Arixtra-free dimer, may suggest that the drug interacts across the two monomers, thereby inhibiting their dissociation.

Entities:  

Year:  2009        PMID: 20160907      PMCID: PMC2769070          DOI: 10.1016/j.ijms.2009.02.023

Source DB:  PubMed          Journal:  Int J Mass Spectrom        ISSN: 1387-3806            Impact factor:   1.986


  42 in total

1.  Anhydrous protein ions.

Authors:  C S Hoaglund-Hyzer; A E Counterman; D E Clemmer
Journal:  Chem Rev       Date:  1999-10-13       Impact factor: 60.622

2.  The effect of the source pressure on the abundance of ions of noncovalent protein assemblies in an electrospray ionization orthogonal time-of-flight instrument.

Authors:  N Tahallah; M Pinkse; C S Maier; A J Heck
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

Review 3.  Investigation of intact protein complexes by mass spectrometry.

Authors:  Albert J R Heck; Robert H H Van Den Heuvel
Journal:  Mass Spectrom Rev       Date:  2004 Sep-Oct       Impact factor: 10.946

Review 4.  Chemokines: multiple levels of leukocyte migration control.

Authors:  Bernhard Moser; Marlene Wolf; Alfred Walz; Pius Loetscher
Journal:  Trends Immunol       Date:  2004-02       Impact factor: 16.687

5.  Tandem mass spectrometry reveals the quaternary organization of macromolecular assemblies.

Authors:  Justin L P Benesch; J Andrew Aquilina; Brandon T Ruotolo; Frank Sobott; Carol V Robinson
Journal:  Chem Biol       Date:  2006-06

Review 6.  Ion mobility-mass spectrometry.

Authors:  Abu B Kanu; Prabha Dwivedi; Maggie Tam; Laura Matz; Herbert H Hill
Journal:  J Mass Spectrom       Date:  2008-01       Impact factor: 1.982

7.  A fundamental introduction to ion mobility mass spectrometry applied to the analysis of biomolecules.

Authors:  Guido F Verbeck; Brandon T Ruotolo; Holly A Sawyer; Kent J Gillig; David H Russell
Journal:  J Biomol Tech       Date:  2002-06

8.  Electrospray interface for liquid chromatographs and mass spectrometers.

Authors:  C M Whitehouse; R N Dreyer; M Yamashita; J B Fenn
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

9.  Glycosaminoglycans mediate cell surface oligomerization of chemokines.

Authors:  A J Hoogewerf; G S Kuschert; A E Proudfoot; F Borlat; I Clark-Lewis; C A Power; T N Wells
Journal:  Biochemistry       Date:  1997-11-04       Impact factor: 3.162

Review 10.  Human monocyte chemoattractant protein-1 (MCP-1).

Authors:  E J Leonard; T Yoshimura
Journal:  Immunol Today       Date:  1990-03
View more
  7 in total

1.  Ion mobility mass spectrometry coupled with rapid protein threading predictor structure prediction and collision-induced dissociation for probing chemokine conformation and stability.

Authors:  Milady R Niñonuevo; Julie A Leary
Journal:  Anal Chem       Date:  2012-03-16       Impact factor: 6.986

2.  Preparation, separation, and conformational analysis of differentially sulfated heparin octasaccharide isomers using ion mobility mass spectrometry.

Authors:  Youjin Seo; Armann Andaya; Julie A Leary
Journal:  Anal Chem       Date:  2012-02-14       Impact factor: 6.986

3.  Biologically Relevant Metal-Cation Binding Induces Conformational Changes in Heparin Oligosaccharides as Measured by Ion Mobility Mass Spectrometry.

Authors:  Youjin Seo; Matthew R Schenauer; Julie A Leary
Journal:  Int J Mass Spectrom       Date:  2011-06-01       Impact factor: 1.986

Review 4.  Lipid analysis and lipidomics by structurally selective ion mobility-mass spectrometry.

Authors:  Michal Kliman; Jody C May; John A McLean
Journal:  Biochim Biophys Acta       Date:  2011-06-25

5.  A competitive binding study of chemokine, sulfated receptor, and glycosaminoglycan interactions by nano-electrospray ionization mass spectrometry.

Authors:  Connie H Jen; Julie A Leary
Journal:  Anal Biochem       Date:  2010-08-07       Impact factor: 3.365

6.  Amphitrite: A program for processing travelling wave ion mobility mass spectrometry data.

Authors:  Ganesh N Sivalingam; Jun Yan; Harpal Sahota; Konstantinos Thalassinos
Journal:  Int J Mass Spectrom       Date:  2013-07-01       Impact factor: 1.986

7.  Structural Evidence for the Tetrameric Assembly of Chemokine CCL11 and the Glycosaminoglycan Arixtra™.

Authors:  Andrew B Dykstra; Matt D Sweeney; Julie A Leary
Journal:  Biomolecules       Date:  2013-11-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.