Scatter and staff dose levels in paediatric interventional cardiology: a multicentre study.

Carlos Ubeda1, Eliseo Vano, Luciano Gonzalez, Patricia Miranda, Edith Valenzuela, Fernando Leyton, Carlos Oyarzun.   

Abstract

Interventional cardiology procedures usually imply high doses to the staff, as paediatric cardiologists need to stay closer to the patient than during adult procedures. Also, biplane systems are used that imply an additional source of staff doses. The objective of this paper is to measure scatter doses in four X-ray systems, using polymethyl methacrylate phantoms with thicknesses ranging from 4 to 16 cm to simulate paediatric patients, for the different acquisition modes. Scatter dose rates measured at the position of cardiologist's eyes ranged from 0.8 to 12 mSv h(-1), and about twice the above values at lower extremities, as a linear function of the surface air kerma at the phantom, keeping the irradiated area constant. Therefore, the respective personal dose equivalent for the lens of the eyes may be around 0.5 and 1 mSv throughout the procedure, if additional protection is not used. Simultaneous cine acquisition in biplane systems yielded scatter doses to cardiologists, increased by factors from 5 to 21, compared with a single C-arm acquisition case and depending on geometry. Knowledge of scatter doses for different operation modes, patient thicknesses and the biplane operation should help paediatric cardiologists to adopt conservative attitudes in respect of their occupational radiation risks.

Entities:  

Mesh:

Year:  2010        PMID: 20159911     DOI: 10.1093/rpd/ncq039

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures.

Authors:  R E R Artschan; D S Brettle; K Chase; A Fender; P G Howells; S Buchan
Journal:  Br J Radiol       Date:  2014-03-06       Impact factor: 3.039

2.  Radiation-induced noncancer risks in interventional cardiology: optimisation of procedures and staff and patient dose reduction.

Authors:  Zhonghua Sun; Aini AbAziz; Ahmad Khairuddin Md Yusof
Journal:  Biomed Res Int       Date:  2013-08-20       Impact factor: 3.411

3.  Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

Authors:  Zaid Alnewaini; Eric Langer; Philipp Schaber; Matthias David; Dominik Kretz; Volker Steil; Jürgen Hesser
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.