Literature DB >> 20159131

Step counting and energy expenditure estimation in patients with chronic obstructive pulmonary disease and healthy elderly: accuracy of 2 motion sensors.

Karina C Furlanetto1, Gianna W Bisca, Nicoli Oldemberg, Thaís J Sant'anna, Fernanda K Morakami, Carlos A Camillo, Vinicius Cavalheri, Nidia A Hernandes, Vanessa S Probst, Ercy M Ramos, Antonio F Brunetto, Fábio Pitta.   

Abstract

OBJECTIVE: To compare the accuracy of 2 motion sensors (a pedometer and a multisensor) in terms of step counting and estimation of energy expenditure (EE) in patients with chronic obstructive pulmonary disease (COPD) and in healthy elderly.
DESIGN: In this descriptive study, all participants wore both motion sensors while performing a treadmill walking protocol at 3 different speeds corresponding to 30%, 60%, and 100% of the average speed achieved during a six-minute walk test. As criterion methods, EE was estimated by indirect calorimetry, and steps were registered by videotape.
SETTING: Research laboratory at a university hospital. PARTICIPANTS: Patients with COPD (n=30; 17 men; mean age +/- SD, 67+/-8 y; mean forced expiratory volume in the first second [FEV(1)] predicted +/- SD, 46%+/-17%; mean body mass index [BMI] +/- SD, 24+/-4 kg.m(2)) and matched healthy elderly (n=30; 15 men; mean age +/- SD, 68+/-7 y; mean FEV(1) predicted +/- SD, 104%+/-21%; mean BMI +/- SD, 25+/-3 kg.m(2)).
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURE: Step counting and EE estimation during a treadmill walking protocol.
RESULTS: The pedometer was accurate for step counting and EE estimation in both patients with COPD and healthy elderly at the higher speed. However, it showed significant underestimation at the 2 slower speeds in both groups. The multisensor did not detect steps accurately at any speed, although it accurately estimated EE at all speeds in healthy elderly and at the intermediate and higher speeds in patients with COPD.
CONCLUSIONS: In both patients with COPD and healthy elderly, the multisensor showed better EE estimates during most walking speeds than the pedometer. Conversely, for step counting, accuracy is observed only with the pedometer during the higher walking speed in both groups. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20159131     DOI: 10.1016/j.apmr.2009.10.024

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  30 in total

1.  Low levels of physical activity are associated with dysregulation of energy intake and fat mass gain over 1 year.

Authors:  Robin P Shook; Gregory A Hand; Clemens Drenowatz; James R Hebert; Amanda E Paluch; John E Blundell; James O Hill; Peter T Katzmarzyk; Timothy S Church; Steven N Blair
Journal:  Am J Clin Nutr       Date:  2015-11-11       Impact factor: 7.045

2.  Oxygen Desaturation in Daily Life and During a Laboratory-Based Protocol of Activities of Daily Living in COPD: Is There Relationship?

Authors:  Thaís Sant'Anna; Leila Donária; Nidia A Hernandes; Karina C Furlanetto; Décio S Barbosa; Rik Gosselink; Fabio Pitta
Journal:  Lung       Date:  2017-11-13       Impact factor: 2.584

3.  Obesity and physical activity in the daily life of patients with COPD.

Authors:  Fabiane Monteiro; Carlos Augusto Camillo; Renato Vitorasso; Thaís Sant'Anna; Nídia A Hernandes; Vanessa S Probst; Fábio Pitta
Journal:  Lung       Date:  2012-03-02       Impact factor: 2.584

Review 4.  Physical Activity Monitoring in Patients with Chronic Obstructive Pulmonary Disease.

Authors:  Shu-Yi Liao; Roberto Benzo; Andrew L Ries; Xavier Soler
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

5.  Measurement of daily physical activity using the SenseWear Armband: Compliance, comfort, adverse side effects and usability.

Authors:  Renae J McNamara; Ling Ling Y Tsai; Sally L Wootton; L W Cindy Ng; Marita T Dale; Zoe J McKeough; Jennifer A Alison
Journal:  Chron Respir Dis       Date:  2016-02-15       Impact factor: 2.444

6.  SenseWearMini and Actigraph GT3X Accelerometer Classification of Observed Sedentary and Light-Intensity Physical Activities in a Laboratory Setting.

Authors:  Lynne M Feehan; Charles H Goldsmith; April Y F Leung; Linda C Li
Journal:  Physiother Can       Date:  2016       Impact factor: 1.037

Review 7.  Using cadence to study free-living ambulatory behaviour.

Authors:  Catrine Tudor-Locke; David A Rowe
Journal:  Sports Med       Date:  2012-05-01       Impact factor: 11.136

8.  Validation and feasibility of a caloric expenditure measuring device in women with early-stage breast cancer.

Authors:  Sarah Waliany; Christina M Dieli-Conwright; Paul H Frankel; Arti Hurria; Joseph Chao; Brian Tiep; Joanne E Mortimer
Journal:  Support Care Cancer       Date:  2014-03-29       Impact factor: 3.603

9.  A study of physical activity comparing people with Charcot-Marie-Tooth disease to normal control subjects.

Authors:  Gita M Ramdharry; Alexander J Pollard; Robert Grant; Elizabeth L Dewar; Matilde Laurá; Sarah A Moore; Kate Hallsworth; Thomas Ploetz; Michael I Trenell; Mary M Reilly
Journal:  Disabil Rehabil       Date:  2016-08-16       Impact factor: 3.033

10.  Changes in physical activity in healthy people and COPD patients.

Authors:  Voicu Tudorache; Cristian Oancea; Claudiu Avram; Ovidiu Fira-Mlădinescu
Journal:  Wien Klin Wochenschr       Date:  2013-11-19       Impact factor: 1.704

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.