Literature DB >> 20158597

Comparison of GSR composition occurring at different locations around the firing position.

Marco R Rijnders1, Amalía Stamouli, Annabel Bolck.   

Abstract

Variations in gunshot residue (GSR) compositions are used in the reconstruction of shooting incidents. In this study, GSR samples taken from seven different locations around and in the firearm were collected and analyzed using scanning electron microscopy/energy dispersive X-ray analysis. Four different types of ammunition were applied. Very low correlations were found when different ammunition were used. This clearly shows that it is possible to differentiate between ammunition types. When the same ammunition was used, high correlations were found between samples taken from external positions (such as hands of shooter, bullet-entrance holes) but poor correlation was found between internal samples (such as firearm barrel, cartridge case) and external samples. A high degree of association was found between samples that simulated victim and shooter. These findings clearly demonstrate that GSR comparison studies are meaningful but care needs to be taken when choosing suitable exhibits. External samples (such as hands of shooter, bullet-entrance holes) are more suitable candidates than internal samples (barrel of the firearm, cartridge case).

Year:  2010        PMID: 20158597     DOI: 10.1111/j.1556-4029.2009.01292.x

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  5 in total

1.  The survival of metallic residues from gunshot wounds in cremated bone: a SEM-EDX study.

Authors:  Alberto Amadasi; Alberto Brandone; Agostino Rizzi; Debora Mazzarelli; Cristina Cattaneo
Journal:  Int J Legal Med       Date:  2012-01-15       Impact factor: 2.686

2.  Identification of polygonal barrel rifling characteristics in bullet wipe residue deposited on textiles.

Authors:  Katherine A Roberts; Galyn Fischer; Amanda R Davis
Journal:  Int J Legal Med       Date:  2019-02-12       Impact factor: 2.686

3.  The detection of gunshot residues in the nasal mucus of suspected shooters.

Authors:  Daniele Merli; Alberto Brandone; Alberto Amadasi; Cristina Cattaneo; Antonella Profumo
Journal:  Int J Legal Med       Date:  2016-05-14       Impact factor: 2.686

Review 4.  Interpol review of gunshot residue 2016-2019.

Authors:  Sébastien Charles; Nadia Geusens; Emeline Vergalito; Bart Nys
Journal:  Forensic Sci Int       Date:  2020-03-12       Impact factor: 2.395

5.  Characterisation of gunshot residues from non-toxic ammunition and their persistence on the shooter's hands.

Authors:  Sabrina Romanò; Fabio De-Giorgio; Carlo D'Onofrio; Luciano Gravina; Sergio Abate; Francesco Saverio Romolo
Journal:  Int J Legal Med       Date:  2020-02-12       Impact factor: 2.686

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.