Literature DB >> 20156231

Ten-year retrospective follow-up study of the TiOblast dental implant.

Bilal Al-Nawas1, Peer W Kämmerer, Thomas Morbach, Catharina Ladwein, Joachim Wegener, Wilfried Wagner.   

Abstract

PURPOSE: Long-term results in the clinical outcome of different implant systems, including high patient numbers and a long follow-up time, are rare. This retrospective study evaluated the cumulative survival rate of a self-tapping, cylindrical implant system with a conical implant-abutment connection after 10 years of prosthetic loading.
MATERIALS AND METHODS: A total of 516 TiOblast implants (Astra Tech AB, Mölndal, Sweden) were placed in 108 patients. The patients were treated in the Department of Oral and Maxillofacial Surgery, Johannes Gutenberg University, Mainz, Germany, between September 1994 and May 2005. The main indications for implantation were the treatment of edentulous mandibles (74%) and partial edentulism (15%). Twenty-three implants were placed postradiation, and a further 64 implants were irradiated after insertion. In 153 implants, a bony augmentation was conducted prior to implantation.
RESULTS: The in situ rate was 89.7% after an average implantation time of 108 months. Eighty-three patients with 403 implants were available for investigation. Seventeen patients with 76 implants have died since 1994. Absence of osseointegration (n = 22), peri-implantitis (n = 18), fracture of the implants (n = 9), failing of primary stability (n = 2), and implants next to tumors (n = 2) were the reasons of explantation in 26 patients. Under analysis with different implant success-assessment criteria, the success rate showed results from 76 to 89%.
CONCLUSION: With respect to the critical patient selection including a high number of patients with minor and major augmentations, the 10-year clinical use of the studied implant system showed acceptable results.
© 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20156231     DOI: 10.1111/j.1708-8208.2009.00237.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  10 in total

1.  Early outcome of an implant system with a resorbable adhesive calcium-phosphate coating--a prospective clinical study in partially dentate patients.

Authors:  Victor Palarie; Constantin Bicer; Karl M Lehmann; Mohammad Zahalka; Florian G Draenert; Peer W Kämmerer
Journal:  Clin Oral Investig       Date:  2011-08-06       Impact factor: 3.573

2.  Influence of gaseous ozone in peri-implantitis: bactericidal efficacy and cellular response. An in vitro study using titanium and zirconia.

Authors:  Irmgard Hauser-Gerspach; Jasminka Vadaszan; Irma Deronjic; Catiana Gass; Jürg Meyer; Michel Dard; Tuomas Waltimo; Stefan Stübinger; Corinna Mauth
Journal:  Clin Oral Investig       Date:  2011-08-13       Impact factor: 3.573

3.  Osseointegration of a New, Ultrahydrophilic and Nanostructured Dental Implant Surface: A Comparative In Vivo Study.

Authors:  Andreas Pabst; Ashraf Asran; Steffen Lüers; Markus Laub; Christopher Holfeld; Victor Palarie; Daniel G E Thiem; Philipp Becker; Amely Hartmann; Diana Heimes; Bilal Al-Nawas; Peer W Kämmerer
Journal:  Biomedicines       Date:  2022-04-19

4.  Surface alterations of zirconia and titanium substrates after Er,Cr:YSGG irradiation.

Authors:  Persio Vasconcelos Miranda; José Augusto Rodrigues; Alberto Blay; Jamil Awad Shibli; Alessandra Cassoni
Journal:  Lasers Med Sci       Date:  2014-01-16       Impact factor: 3.161

5.  Dense cancellous bone as evidenced by a high HU value is predictive of late implant failure: a preliminary study.

Authors:  Ikuya Miyamoto; Tetsu Takahashi; Tatsurou Tanaka; Bunichi Hirayama; Kenko Tanaka; Toru Yamazaki; Yasuhiro Morimoto; Izumi Yoshioka
Journal:  Oral Radiol       Date:  2017-08-03       Impact factor: 1.852

6.  Guided Bone Regeneration Using Collagen Scaffolds, Growth Factors, and Periodontal Ligament Stem Cells for Treatment of Peri-Implant Bone Defects In Vivo.

Authors:  Peer W Kämmerer; Malte Scholz; Maria Baudisch; Jan Liese; Katharina Wegner; Bernhard Frerich; Hermann Lang
Journal:  Stem Cells Int       Date:  2017-08-16       Impact factor: 5.443

7.  Clinical outcome of alveolar ridge augmentation with individualized CAD-CAM-produced titanium mesh.

Authors:  K Sagheb; E Schiegnitz; M Moergel; C Walter; B Al-Nawas; W Wagner
Journal:  Int J Implant Dent       Date:  2017-07-26

8.  Clinical and radiographic evaluation of new dental implant system: Results of a 3-year prospective study.

Authors:  Seçil Karakoca Nemli; Merve Bankoğlu Güngör; Cemal Aydın; Handan Yılmaz; Bilge Turhan Bal; Yeliz Kaşko Arıcı
Journal:  J Dent Sci       Date:  2015-05-15       Impact factor: 2.080

9.  Long-Term Treatment Outcomes of Implant Prostheses in Partially and Totally Edentulous Patients.

Authors:  Eugenio Velasco-Ortega; Inmaculada Del Rocío Jiménez-Martin; Jesús Moreno-Muñoz; Enrique Núñez-Márquez; José Luis Rondón-Romero; Daniel Cabanillas-Balsera; Álvaro Jiménez-Guerra; Iván Ortiz-García; José López-López; Loreto Monsalve-Guil
Journal:  Materials (Basel)       Date:  2022-07-14       Impact factor: 3.748

10.  Combined use of miniscrews and continuous arch for intrusive root movement of incisors in Class II division 2 with gummy smile.

Authors:  Sung-Jin Kim; Jin-Wook Kim; Tae-Hyun Choi; Kee-Joon Lee
Journal:  Angle Orthod       Date:  2014-02-07       Impact factor: 2.079

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.