Literature DB >> 20154537

Safety evaluation of new hemostatic agents, smectite granules, and kaolin-coated gauze in a vascular injury wound model in swine.

Bijan S Kheirabadi1, James E Mace, Irasema B Terrazas, Chriselda G Fedyk, J Scot Estep, Michael A Dubick, Lorne H Blackbourne.   

Abstract

BACKGROUND: In 2007, a potent procoagulant mineral called WoundStat (WS), consisting of smectite granules, received clearance from the Food and Drug Administration for marketing in the United States for temporary treatment of external hemorrhage. Previously, we found that microscopic WS particles remained in the injured vessels that were treated, despite seemingly adequate wound debridement. Thus, we investigated the thromboembolic risk of using WS when compared with kaolin-coated gauze, Combat Gauze (CG); or regular gauze, Kerlix (KX) to treat an external wound with vascular injuries in pigs.
METHODS: The right common carotid artery and external jugular vein of pigs were isolated and sharply transected (50%). After 30 seconds of free bleeding, the neck wounds were packed with WS, CG, or KX and compressed until hemostasis was achieved (n = 8 per group). Wounds were debrided after 2 hours, and vascular injuries were primarily repaired with suture. Blood flow was restored after infusing 1 L of crystalloid (no heparin or aspirin) and the wounds were closed. Two hours later, computed tomographic angiography was performed, and the wounds were reopened to harvest the vessels. The brains and lungs were recovered for gross and microscopic examination after euthanasia.
RESULTS: No differences were found in baseline measurements. Thrombelastography showed similar hypercoagulability of the final blood samples when compared with baselines in all groups. All vessels treated with KX or CG were patent and had no thrombus or blood clot in their lumen. In contrast, seven of eight carotid arteries and six of eight jugular veins treated with WS developed large occlusive red thrombi and had no flow. Small clots and WS residues were also found in the lungs of two pigs. Histologically, significant endothelial and transmural damage was seen in WS-treated vessels with luminal thrombi and embedded WS residues.
CONCLUSION: WS granules caused endothelial injury and significant transmural damage to the vessels that render them nonviable for primary surgical repair. The granules can enter systemic circulation and cause distal thrombosis in vital organs. More relevant in vitro and in vivo safety tests should be required for clearance of new hemostatic agents.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20154537     DOI: 10.1097/TA.0b013e3181c97ef1

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  25 in total

Review 1.  Tactical combat casualty care in the Canadian Forces: lessons learned from the Afghan war.

Authors:  Erin Savage; Colleen Forestier; Nicholas Withers; Homer Tien; Dylan Pannell
Journal:  Can J Surg       Date:  2011-12       Impact factor: 2.089

2.  Tubeless percutaneous nephrolithotomy with non-absorbable hemostatic sealant (Quikclot®) versus nephrostomy tube placement: a propensity score-matched analysis.

Authors:  Kyo Chul Koo; Sang Un Park; Ho Sung Jang; Chang-Hee Hong
Journal:  Urolithiasis       Date:  2015-06-30       Impact factor: 3.436

3.  The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution and hypothermia.

Authors:  Don Johnson; Sheri Bates; Sofiya Nukalo; Amy Staub; Aaron Hines; Taylor Leishman; Jennifer Michel; Dusti Sikes; Brian Gegel; James Burgert
Journal:  Ann Med Surg (Lond)       Date:  2014-03-26

Review 4.  Topical and effective hemostatic medicines in the battlefield.

Authors:  Yin-Juan Zhang; Bo Gao; Xi-Wen Liu
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 5.  [Approaches to pre-hospital bleeding management : Current overview on civilian emergency medicine].

Authors:  H Lier; M Bernhard; J Knapp; C Buschmann; I Bretschneider; B Hossfeld
Journal:  Anaesthesist       Date:  2017-11       Impact factor: 1.041

Review 6.  Role of hemostatic powders in the endoscopic management of gastrointestinal bleeding.

Authors:  Marco Bustamante-Balén; Gema Plumé
Journal:  World J Gastrointest Pathophysiol       Date:  2014-08-15

7.  A hydrogel sealant for the treatment of severe hepatic and aortic trauma with a dissolution feature for post-emergent care.

Authors:  Marlena D Konieczynska; Juan C Villa-Camacho; Cynthia Ghobril; Miguel Perez-Viloria; William A Blessing; Ara Nazarian; Edward K Rodriguez; Mark W Grinstaff
Journal:  Mater Horiz       Date:  2016-12-23       Impact factor: 13.266

8.  Hemostatic gauze based on chitosan and hydroquinone: preparation, characterization and blood coagulation evaluation.

Authors:  Roberta Cassano; Maria Luisa Di Gioia; Silvia Mellace; Nevio Picci; Sonia Trombino
Journal:  J Mater Sci Mater Med       Date:  2017-11-07       Impact factor: 3.896

9.  Materials design at the interface of nanoparticles and innate immunity.

Authors:  Gregory Lee Szeto; Erin B Lavik
Journal:  J Mater Chem B       Date:  2016-01-29       Impact factor: 6.331

Review 10.  Biomaterials and Advanced Technologies for Hemostatic Management of Bleeding.

Authors:  DaShawn A Hickman; Christa L Pawlowski; Ujjal D S Sekhon; Joyann Marks; Anirban Sen Gupta
Journal:  Adv Mater       Date:  2017-11-22       Impact factor: 30.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.