Literature DB >> 20153703

Determination of melamine and cyanuric acid in human urine by a liquid chromatography tandem mass spectrometry.

Mengqi Zhang1, Shuijun Li, Chengyin Yu, Gangyi Liu, Jingying Jia, Chuan Lu, Jian He, Yinghua Ma, Jianmin Zhu, Chen Yu.   

Abstract

Melamine was found to be the etiological factor for the urinary stones epidemic in infants and young children in China in 2008. Urine level of melamine and its analog cyanuric acid may be useful markers for the evaluation of toxic effects. Liquid chromatography tandem mass spectrometry methods for the individual determination of melamine and cyanuric acid in human urine are described. Using isotope labeled internal standards during liquid-liquid extraction, the method was fully validated by verifying specificity, linearity, LLOQ, intra- and inter-assay precision and accuracy, matrix effect, recovery and stability. Calibration curves with good linearity (r=0.9999) over the concentration range from 10 to 5000 ng/ml, intra-assay precision <10% and inter-assay precision <15%, accuracy between 93.0 and 111.6% were obtained with multiple reaction monitoring mode for melamine and cyanuric acid in human urine. The methods were successfully applied to the analysis of urine samples collected from 86 infants and 110 adults. 2010. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20153703     DOI: 10.1016/j.jchromb.2010.01.020

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

1.  A highly sensitive aptamer-nanogold catalytic resonance scattering spectral assay for melamine.

Authors:  Aihui Liang; Lianping Zhou; Huimin Qin; Yi Zhang; Huixiang Ouyang; Zhiliang Jiang
Journal:  J Fluoresc       Date:  2011-04-26       Impact factor: 2.217

2.  Inter-day and inter-individual variability in urinary concentrations of melamine and cyanuric acid.

Authors:  Hongkai Zhu; Kurunthachalam Kannan
Journal:  Environ Int       Date:  2018-12-17       Impact factor: 9.621

3.  Ambient Melamine Exposure and Urinary Biomarkers of Early Renal Injury.

Authors:  Chia-Fang Wu; Chiung-Yu Peng; Chia-Chu Liu; Wen-Yi Lin; Chih-Hong Pan; Ching-Mei Cheng; Hui-Min Hsieh; Tusty-Jiuan Hsieh; Bai-Hsiun Chen; Ming-Tsang Wu
Journal:  J Am Soc Nephrol       Date:  2015-06-04       Impact factor: 10.121

4.  Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

Authors:  Ricardo Cantú; Jody A Shoemaker; Catherine A Kelty; Larry J Wymer; Thomas D Behymer; Alfred P Dufour; Matthew L Magnuson
Journal:  Anal Chim Acta       Date:  2017-06-19       Impact factor: 6.558

5.  Chemiluminescence determination of melamine with Luminol-K3Fe(CN)6 system.

Authors:  Xiao-Shuang Tang; Xi-Yan Shi; Yu-Hai Tang; Zhong-Jin Yue; Qi-Qi He
Journal:  J Pharm Anal       Date:  2012-01-30

6.  Determination of melamine in soil samples using surfactant-enhanced hollow fiber liquid phase microextraction followed by HPLC-UV using experimental design.

Authors:  Ali Sarafraz Yazdi; Samaneh Raouf Yazdinezhad; Tahereh Heidari
Journal:  J Adv Res       Date:  2014-11-08       Impact factor: 10.479

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.