Literature DB >> 2015134

Nonunion of a comminuted intra-articular wrist fracture after external fixation. A case report and review of the literature.

E Verhaven1, P Haentjens, P P Casteleyn, H De Boeck, P Opdecam.   

Abstract

Nonunion is a very rare complication of a comminuted intra-articular wrist fracture treated by external fixation. The authors describe the likely reasons and the after-care, in order to avoid this complication.

Entities:  

Mesh:

Year:  1991        PMID: 2015134     DOI: 10.1007/bf00393887

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  22 in total

1.  External fixation of wrist fractures.

Authors:  F Schuind; M Donkerwolcke; F Burny
Journal:  Orthopedics       Date:  1984-05-01       Impact factor: 1.390

2.  Colles fracture: does the anatomical result affect the final function?

Authors:  M McQueen; J Caspers
Journal:  J Bone Joint Surg Br       Date:  1988-08

3.  [Pseudarthrosis of the lower end of the radius due to interposition of the long extensor of the thumb].

Authors:  J Y de La Caffinière; M Bex; J P Rengeval
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1986

4.  [Use of an external metacarporadial fixation device for the treatment of severe fractures of the lower end of the radius (author's transl)].

Authors:  J M Thomine; M Demesy
Journal:  Ann Chir       Date:  1979

Review 5.  Comminuted intraarticular fractures of the distal radius.

Authors:  R M Szabo; S C Weber
Journal:  Clin Orthop Relat Res       Date:  1988-05       Impact factor: 4.176

6.  External fixation of distal radial fractures.

Authors:  W P Cooney
Journal:  Clin Orthop Relat Res       Date:  1983-11       Impact factor: 4.176

7.  External fixation of complex hand and wrist fractures.

Authors:  S A Riggs; W P Cooney
Journal:  J Trauma       Date:  1983-04

8.  External fixation of Colles' fractures. An anatomical study.

Authors:  N H Jenkins; D G Jones; S R Johnson; W J Mintowt-Czyz
Journal:  J Bone Joint Surg Br       Date:  1987-03

9.  The external fixation treatment of distal articular fractures of the radius.

Authors:  L Ricciardi; W Diquigiovanni
Journal:  Orthopedics       Date:  1984-04-01       Impact factor: 1.390

10.  The Roger Anderson device in the treatment of fractures of the distal end of the radius.

Authors:  W A Grana; J A Kopta
Journal:  J Bone Joint Surg Am       Date:  1979-12       Impact factor: 5.284

View more