Literature DB >> 20149282

A low cost time-resolved Raman spectroscopic sensing system enabling fluorescence rejection.

Joseph V Sinfield1, Oliver Colic, Daniel Fagerman, Chike Monwuba.   

Abstract

This paper describes a novel, compact, fiber-coupled, time-resolved Raman spectroscopy system that takes advantage of recent developments in diode laser and data acquisition technology to exploit the natural temporal separation between Raman and fluorescence phenomena and thereby limits the influence of fluorescence on Raman observations. The unit has been designed to be particularly low cost and is intended to provide the foundation for a wide range of in-line or fieldable sensing devices that can enhance the potential and affordability of in situ chemical analyses. The system operating principles, design, and performance are discussed along with its advantages and tradeoffs relative to traditional continuous wave (CW) Raman techniques. The system relies on a 6.4 kHz repetition rate 900 ps pulsed diode laser operating in the visible wavelength range (532 nm) to enhance the quality of Raman observations relative to CW and infrared systems, particularly for analytes examined in the presence of fluorophores. Time-resolved photon counting, achieved through a combination of off-the-shelf and custom hardware and software, limits the influence of fluorescence on Raman observations under pulsed excitation. The paper presents examples of the quality of Raman signatures that can be obtained with the system for a variety of compounds such as trichloroethylene, benzene, an aqueous nitrate solution, and olive oil. Further, the paper demonstrates an approximately 15-fold improvement in signal-to-noise ratio when comparing long- and short-gated time-resolved photon counting acquisition scenarios for a neat benzene sample doped with rhodamine 6G at a concentration of 1 x 10(-4) M. The system's versatility and effectiveness in the assessment of complex mixtures representative of industrial or field settings is demonstrated through analysis of a gasoline sample. Additional discussion outlines how efficient signal averaging over extended observation periods can enable low concentration chemical analyses, particularly relevant in field settings.

Entities:  

Year:  2010        PMID: 20149282     DOI: 10.1366/000370210790619636

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  2 in total

Review 1.  Modulated Raman Spectroscopy for Enhanced Cancer Diagnosis at the Cellular Level.

Authors:  Anna Chiara De Luca; Kishan Dholakia; Michael Mazilu
Journal:  Sensors (Basel)       Date:  2015-06-11       Impact factor: 3.576

Review 2.  Raman spectroscopy for in-line water quality monitoring--instrumentation and potential.

Authors:  Zhiyun Li; M Jamal Deen; Shiva Kumar; P Ravi Selvaganapathy
Journal:  Sensors (Basel)       Date:  2014-09-16       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.