Literature DB >> 20148916

Immediate occlusal loading of NanoTite PREVAIL implants: a prospective 1-year clinical and radiographic study.

Pär-Olov Ostman1, Ann Wennerberg, Tomas Albrektsson.   

Abstract

BACKGROUND: Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. AIM: The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions.
MATERIALS AND METHODS: Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months.
RESULTS: Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants.
CONCLUSION: Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20148916     DOI: 10.1111/j.1708-8208.2008.00128.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  4 in total

1.  Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla.

Authors:  Lieven Barbier; Johan Abeloos; Calix De Clercq; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2011-09-20       Impact factor: 3.573

2.  Does Biphasic Calcium Phosphate-Coated Surface Increase the Secondary Stability in Dental Implants? A Split-Mouth Study.

Authors:  Reza Tabrizi; Hassan Mirmohammad Sadeghi; Kimia Ghasemi; Adel Khayati; Mohammad Jafarian
Journal:  J Maxillofac Oral Surg       Date:  2020-09-24

3.  Nonlinear finite element analysis of three implant- abutment interface designs.

Authors:  Chun-Bo Tang; Si-Yu Liul; Guo-Xing Zhou; Jin-Hua Yu; Guang-Dong Zhang; Yi-Dong Bao; Qiu-Ju Wang
Journal:  Int J Oral Sci       Date:  2012-06       Impact factor: 6.344

4.  Early marginal bone stability of dental implants placed in a transalveolarly augmented maxillary sinus: a controlled retrospective study of surface modification with calcium ions.

Authors:  Eduardo Anitua; Laura Piñas; Mohammad Hamdan Alkhraisat
Journal:  Int J Implant Dent       Date:  2017-12-04
  4 in total