Literature DB >> 20147815

Finite element analysis of 2 immediate loading systems in edentulous mandible: rigid and semirigid splinting of implants.

Marcelo Fontes Teixeira1, Saturnino Aparecido Ramalho, Ivete Aparecida de Mattias Sartori, Roberto Brunow Lehmann.   

Abstract

PURPOSE: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). METHODS AND MATERIALS: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element.
RESULTS: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading.
CONCLUSION: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur.

Entities:  

Mesh:

Year:  2010        PMID: 20147815     DOI: 10.1097/ID.0b013e3181cc7ffc

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  2 in total

1.  Semirigid cantilever extension system for splinting implants: a clinical report.

Authors:  Raissa Micaella Marcello Machado; Luciana de Rezende Pinto; Otacílio Luiz Chagas Júnior; Fernanda Faot
Journal:  Case Rep Dent       Date:  2014-08-05

2.  Finite Element Analysis of Stress in Anterior Prosthetic Rehabilitation with Zirconia Implants with and without Cantilever.

Authors:  Karina Tiemi Sanomya Tsumanuma; Ricardo Armini Caldas; Isaias Donizeti Silva; Milton Edson Miranda; William Cunha Brandt; Rafael Pino Vitti
Journal:  Eur J Dent       Date:  2021-08-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.