Literature DB >> 20146373

Application of variable-rate selective excitation pulses for spin labeling in perfusion MRI.

Jiabao He1, Andrew M Blamire.   

Abstract

Arterial spin labeling offers great potential in clinical applications for noninvasive measurement of cerebral blood flow. Arterial spin labeling tagging methods such as the flow sensitive alternating inversion recovery technique require efficient spatial inversion pulses with high inversion accuracy and sharp transition zones between inverted and noninverted magnetization, i.e., require a high performance inversion pulse. This work presents a comprehensive comparison of the advantages offered by a variable-rate selective excitation variant of the hyperbolic secant pulse against the widely used conventional hyperbolic secant pulse and the frequency offset corrected inversion pulses. Pulses were compared using simulation and experimental measurement in phantoms before being used in a flow sensitive alternating inversion recovery-arterial spin labeling perfusion measurement in normal volunteers. Both the hyperbolic secant and frequency offset corrected inversion pulses have small variations in inversion profiles that may lead to unwanted subtraction errors in arterial spin labeling at a level where the residual signal is comparable to the desired perfusion contrast. The variable-rate selective excitation pulse is shown to have improved inversion efficiency indicating its potential in perfusion MRI. The variable-rate selective excitation pulse variant also showed greatest tolerance to radiofrequency variation and off-resonance conditions, making it a robust choice for in vivo arterial spin labeling measurement. (c) 2010 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2010        PMID: 20146373     DOI: 10.1002/mrm.22251

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit.

Authors:  Neville D Gai; John A Butman
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

2.  Cerebral vascular control is associated with skeletal muscle pH in chronic fatigue syndrome patients both at rest and during dynamic stimulation.

Authors:  Jiabao He; Kieren G Hollingsworth; Julia L Newton; Andrew M Blamire
Journal:  Neuroimage Clin       Date:  2013-01-05       Impact factor: 4.881

3.  Intracranial compliance is associated with symptoms of orthostatic intolerance in chronic fatigue syndrome.

Authors:  Andreas Finkelmeyer; Jiabao He; Laura Maclachlan; Andrew M Blamire; Julia L Newton
Journal:  PLoS One       Date:  2018-07-03       Impact factor: 3.240