Literature DB >> 20146233

Assessment of arterial arrival times derived from multiple inversion time pulsed arterial spin labeling MRI.

Bradley J MacIntosh1, Nicola Filippini, Michael A Chappell, Mark W Woolrich, Clare E Mackay, Peter Jezzard.   

Abstract

The purpose of this study was to establish a normal range for the arterial arrival time (AAT) in whole-brain pulsed arterial spin labeling (PASL) cerebral perfusion MRI. Healthy volunteers (N = 36, range: 20 to 35 years) provided informed consent to participate in this study. AAT was assessed in multiple brain regions, using three-dimensional gradient and spin echo (GRASE) pulsed arterial spin labeling at 3.0 T, and found to be 641 +/- 95, 804 +/- 91, 802 +/- 126, and 935 +/- 108 ms in the temporal, parietal, frontal, and occipital lobes, respectively. Mean gray matter AAT was found to be 694 +/- 89 ms for females (N = 15), which was significantly shorter than for men, 814 +/- 192 ms (N = 21; P < 0.0003), and significant after correcting for brain volume (P < 0.001). Significant AAT sex differences were also found using voxelwise permutation testing. An atlas of AAT values across the healthy brain is presented here and may be useful for future experiments that aim to quantify cerebral blood flow from ASL data, as well as for clinical comparisons where disease pathology may lead to altered AAT. Pulsed arterial spin labeling signals were simulated using an identical sampling scheme as the empiric study and revealed AAT can be estimated robustly when simulated arrival times are well beyond the normal range. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20146233     DOI: 10.1002/mrm.22256

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  64 in total

1.  Magnetisation transfer effects of Q2TIPS pulses in ASL.

Authors:  Enrico De Vita; Matthias Günther; Xavier Golay; David L Thomas
Journal:  MAGMA       Date:  2011-12-28       Impact factor: 2.310

2.  Complex relationships between cerebral blood flow and brain atrophy in early Huntington's disease.

Authors:  J Jean Chen; David H Salat; H Diana Rosas
Journal:  Neuroimage       Date:  2011-09-16       Impact factor: 6.556

3.  Arterial spin labeling in neuroimaging.

Authors:  Sasitorn Petcharunpaisan; Joana Ramalho; Mauricio Castillo
Journal:  World J Radiol       Date:  2010-10-28

4.  Comparison of arterial spin labeling and bolus perfusion-weighted imaging for detecting mismatch in acute stroke.

Authors:  Greg Zaharchuk; Ibraheem S El Mogy; Nancy J Fischbein; Gregory W Albers
Journal:  Stroke       Date:  2012-04-26       Impact factor: 7.914

5.  Arterial spin-labeling evaluation of cerebrovascular reactivity to acetazolamide in healthy subjects.

Authors:  Y Inoue; Y Tanaka; H Hata; T Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-12-26       Impact factor: 3.825

Review 6.  The physics of functional magnetic resonance imaging (fMRI).

Authors:  Richard B Buxton
Journal:  Rep Prog Phys       Date:  2013-09-04

7.  3D GRASE pulsed arterial spin labeling at multiple inflow times in patients with long arterial transit times: comparison with dynamic susceptibility-weighted contrast-enhanced MRI at 3 Tesla.

Authors:  Steve Z Martin; Vince I Madai; Federico C von Samson-Himmelstjerna; Matthias A Mutke; Miriam Bauer; Cornelius X Herzig; Stefan Hetzer; Matthias Günther; Jan Sobesky
Journal:  J Cereb Blood Flow Metab       Date:  2014-11-19       Impact factor: 6.200

8.  Comparison of PASL, PCASL, and background-suppressed 3D PCASL in mild cognitive impairment.

Authors:  Sudipto Dolui; Marta Vidorreta; Ze Wang; Ilya M Nasrallah; Abass Alavi; David A Wolk; John A Detre
Journal:  Hum Brain Mapp       Date:  2017-07-24       Impact factor: 5.038

9.  Cerebral arterial time constant calculated from the middle and posterior cerebral arteries in healthy subjects.

Authors:  Agnieszka Uryga; Magdalena Kasprowicz; Małgorzata Burzyńska; Leanne Calviello; Katarzyna Kaczmarska; Marek Czosnyka
Journal:  J Clin Monit Comput       Date:  2018-10-05       Impact factor: 2.502

Review 10.  Noise concerns and post-processing procedures in cerebral blood flow (CBF) and cerebral blood volume (CBV) functional magnetic resonance imaging.

Authors:  Manus J Donahue; Meher R Juttukonda; Jennifer M Watchmaker
Journal:  Neuroimage       Date:  2016-09-11       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.