| Literature DB >> 20145733 |
Hongwei Zhang1, Zhaoxiang Bian, Zhixiu Lin.
Abstract
BACKGROUND: The results of many clinical trials and experimental studies regarding acupoint specificity are contradictory. This review aims to investigate whether a difference in efficacy exists between ordinary acupuncture on specific acupoints and sham acupuncture controls on non-acupoints or on irrelevant acupoints.Entities:
Year: 2010 PMID: 20145733 PMCID: PMC2818640 DOI: 10.1186/1749-8546-5-1
Source DB: PubMed Journal: Chin Med ISSN: 1749-8546 Impact factor: 5.455
Figure 1Flow chart showing the retrieval process of clinical trial reports included in the systematic review.
Trial quality of randomized controlled trials with sham acupuncture control
| Trial ID | Risk of bias | Sample size/based on calculationa | Primary outcome | Resultb |
|---|---|---|---|---|
| Huang 2008 [ | Unclear | 120/No | Global symptoms | + |
| Flachskampf 2007 [ | Unclear | 160/Yes | Average systolic and diastolic blood pressure | + |
| Vincent 2007 [ | Low | 103/Yes | Hot flash scores | - |
| Assefi 2005 [ | Low | 100/Yes | Pain (VAS scores) | - |
| Emmons 2005 [ | Low | 85/Yes | Number of incontinent episodes | - |
| Forbes 2005 [ | Low | 59/Yes | Self-rated symptom scores | - |
| Karst 2004 [ | Unclear | 54/unkown | Pain intensity | + |
| Fink 2002 [ | Low | 45/Yes | Pain (VAS scores) | + |
| Smith 2002 [ | Low | 593/Yes | Nausea (self-rated) | - |
| Fireman 2001 [ | High | 32/No | Overall symptoms (VAS scores) | + |
| Wang 2000 [ | Unclear | 132/No | Pain (VAS scores) | + |
| Biernacki 1998 [ | Unclear | 23/No | Spirometric value | - |
a Sample size calculation based on the power analysis intended to detect the difference between proper and sham acupuncture treatment.
b"+" means that the trial detected different outcomes between proper and sham acupuncture; "-" denotes that a trial did not detect different outcomes between proper and sham acupuncture.
c The proper acupuncture treatment was compared to the pooled sham acupuncture groups (including acupuncture for an unrelated condition, needle insertion at non-acupoints, or noninsertive simulated acupuncture).