Measurement of migration of soft tissue by modified Roentgen stereophotogrammetric analysis (RSA): validation of a new technique to monitor rotator cuff tears.

P M M Cashman1, T Baring, P Reilly, R J H Emery, A A Amis.   

Abstract

The purpose of this study was to develop a technique to use Roentgen stereophotogrammetric analysis (RSA) to measure migration of soft-tissue structures after rotator cuff repair. RSA stereo films were obtained; images were analysed using a semi-automatic software program allowing 3D viewing of results. RSA imaging experiments were performed to validate the technique, using a glass phantom with implanted RSA beads and an animal model with steel sutures as RSA markers which were moved known distances. Repeated measurements allowed assessment of inter- and intra-observer variability at a maximum of 1.06 mm. RSA analysis of the phantom showed a variation up to 0.22 mm for static and 0.28 mm for dynamic studies. The ovine tissue specimen demonstrated that using steel sutures as RSA markers in soft tissue is feasible, although less accurate than when measuring bone motion. This novel application of RSA to measure soft tissue migration is practicable and can be extended to in vivo studies.

Entities:  

Mesh:

Year:  2010        PMID: 20143960     DOI: 10.3109/03091900903174428

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  4 in total

1.  Emerging ideas: soft tissue applications of radiostereometric analysis.

Authors:  Lucian B Solomon; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2010-11-23       Impact factor: 4.176

2.  Estimation of dynamic, in vivo soft-tissue deformation: experimental technique and application in a canine model of tendon injury and repair.

Authors:  Michael J Bey; Stephanie K Kline; Andrew R Baker; Jesse A McCarron; Joseph P Iannotti; Kathleen A Derwin
Journal:  J Orthop Res       Date:  2010-12-23       Impact factor: 3.494

3.  Biplanar High-Speed Fluoroscopy of Pony Superficial Digital Flexor Tendon (SDFT)-An In Vivo Pilot Study.

Authors:  Franziska C Wagner; Kerstin Gerlach; Sandra M Geiger; Claudia Gittel; Peter Böttcher; Christoph K W Mülling
Journal:  Vet Sci       Date:  2021-05-27

4.  A novel radiopaque tissue marker for soft tissue localization and in vivo length and area measurements.

Authors:  Sambit Sahoo; Andrew R Baker; Bong Jae Jun; Ahmet Erdemir; Eric T Ricchetti; Joseph P Iannotti; Kathleen A Derwin
Journal:  PLoS One       Date:  2019-10-18       Impact factor: 3.240