Literature DB >> 20143224

Screening of pesticides in blood with liquid chromatography-linear ion trap mass spectrometry.

Sylvain Dulaurent1, Christian Moesch, Pierre Marquet, Jean-Michel Gaulier, Gérard Lachâtre.   

Abstract

In clinical or forensic toxicology, general unknown screening procedures are used to identify as many xenobiotics as possible, belonging to numerous chemical classes. We present here a general unknown screening procedure based on liquid chromatography coupled with use of a single linear ion trap mass spectrometer, and focus on the identification of pesticides and/or metabolites in whole blood. After solid-phase extraction (SPE), the compounds of interest were separated using a reversed-phase column and identified by the mass spectrometer operated first in the full-scan mass spectrometry (MS) mode, in the positive and negative polarities, followed by MS(2) and MS(3) scanning of ions selected in data-dependent acquisition. The total scan time was 2.45 s. Two mass spectral libraries (MS(2) and MS(3)), each of 450 spectra, were created for the 320 pesticides and metabolites detected after injection of pure solutions. Robustness of the spectra and matrix effects were studied and were satisfactory for the present application. Detection limits for the 320 compounds were studied by extracting 1 mL spiked blood at concentrations between 10 microg/L and 10 mg/L. If necessary, it was possible to decrease the detection limits of some compounds by 10-100-fold by scanning MS(2) in only one polarity, owing to a shorter total scan time. However, at the same time, the detection specificity decreased as no confirmation could be recorded in the following MS(3) scan and no information could be registered in the other polarity. So, in these rare cases, confirmation by another method was required.

Mesh:

Substances:

Year:  2010        PMID: 20143224     DOI: 10.1007/s00216-009-3443-z

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Performance of a halo ion trap mass analyzer with exit slits for axial ejection.

Authors:  Miao Wang; Hannah E Quist; Brett J Hansen; Ying Peng; Zhiping Zhang; Aaron R Hawkins; Alan L Rockwood; Daniel E Austin; Milton L Lee
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-15       Impact factor: 3.109

2.  Metabolite identification and quantitation in LC-MS/MS-based metabolomics.

Authors:  Jun Feng Xiao; Bin Zhou; Habtom W Ressom
Journal:  Trends Analyt Chem       Date:  2012-02-01       Impact factor: 12.296

3.  Determination of Picomolar Concentrations of Paraoxon in Human Urine by Fluorescence-Based Enzymatic Assay.

Authors:  Giovanni Paolo Cetrangolo; Carla Gori; Janis Rusko; Sara Terreri; Giuseppe Manco; Amelia Cimmino; Ferdinando Febbraio
Journal:  Sensors (Basel)       Date:  2019-11-07       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.