[Effects of electromagnetic pulse on blood-brain barrier permeability and tight junction proteins in rats].

Lian-bo Qiu1, Gui-rong Ding, Ya-mei Zhang, Yan Zhou, Xiao-wu Wang, Kang-chu Li, Sheng-long Xu, Juan Tan, Jia-xing Zhou, Guo-zhen Guo.   

Abstract

OBJECTIVE: To study the effect of electromagnetic pulse (EMP) on the permeability of blood-brain barrier, tight junction (TJ)-associated protein expression and localization in rats.
METHODS: 66 male SD rats, weighing (200 approximately 250) g, were sham or whole-body exposed to EMP at 200 kV/m for 200 pulses. The repetition rate was 1 Hz. The permeability of the blood-brain barrier in rats was assessed by albumin immunohistochemistry. The expression of typical tight junction protein ZO-1 and occludin in both cerebral cortex homogenate and cerebral cortex microvessel homogenate was analyzed by the Western blotting and the distribution of ZO-1 and occludin was examined by immunofluorescence microscopy.
RESULTS: In the sham exposure rats, no brain capillaries showed albumin leakage, at 0.5 h after 200 kV/m EMP exposure for 200 pulses; a few brain capillaries with extravasated serum albumin was found, with the time extended, the number of brain capillaries with extravasated serum albumin increased, and reached the peak at 3 h, then began to recover at 6 h. In addition, no change in the distribution of the occludin was found after EMP exposure. Total occludin expression had no significant change compared with the control. However, the expression level of ZO-1 significantly decreased at 1 h and 3 h after EMP exposure in both cerebral cortex homogenate and cerebral cortex microvessel homogenate. Furthermore, immunofluorescence studies also showed alterations in ZO-1 protein localization in cerebral cortex microvessel.
CONCLUSION: The EMP exposure (200 kV/m, 200 pulses) could increase blood-brain barrier permeability in rat, and this change is associated with specific alterations in tight junction protein ZO-1.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20137299

Source DB:  PubMed          Journal:  Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi        ISSN: 1001-9391


  1 in total

1.  Activation of VEGF/Flk-1-ERK Pathway Induced Blood-Brain Barrier Injury After Microwave Exposure.

Authors:  Li-Feng Wang; Xiang Li; Ya-Bing Gao; Shui-Ming Wang; Li Zhao; Ji Dong; Bin-Wei Yao; Xin-Ping Xu; Gong-Min Chang; Hong-Mei Zhou; Xiang-Jun Hu; Rui-Yun Peng
Journal:  Mol Neurobiol       Date:  2014-09-09       Impact factor: 5.590