Our purposes were to report the radiographic outcomes and complications of patients with Colles' fracture treated with the Nakashima locking volar plate system (variable angled distal screw locking mechanism) prospectively and to report the results of objective clinical variables such as grip strength and range of motion of the wrist prospectively at up to one year. This study consisted of eight men and 32 women for analysis of radiographic parameters (volar tilt, radial inclination and radial length) and complications. Radiographic parameters were measured pre-operatively, immediately post-operatively and at final follow-up visit. The average age at operation was 60.3 years old. Among them, we selected 25 cases (6 men and 19 women) whom we followed up at six weeks, three months, six months and one year post-operatively. The average age at operation in this group was 62 years old. We measured objective clinical variables (grip strength, forearm rotation, wrist extension/flexion) at each visit. Except for volar tilt, radiographic parameters revealed no significant changes between immediately post-operative radiographs and radiographs at final follow-up visit. Complications included loss of reduction in two cases. Objective clinical variables other than pronation measurement showed significant increase at each visit up to one year post-operatively. Satisfactory clinical and radiographic results were obtained by using this system. The variable angled distal fragment plating system appears to be a reliable construct for rigid fixation of Colles' fractures; however, technical errors can occur, as with other fixation systems. We demonstrated that the follow-up of Colles' fracture treated by our volar locking plate less than one year post-operative may be insufficient.

Entities:  

Mesh:

Year:  2009        PMID: 20135735     DOI: 10.1142/S021881040900430X

Source DB:  PubMed          Journal:  Hand Surg        ISSN: 0218-8104


  2 in total

1.  A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating.

Authors:  Yih-Shiunn Lee; Tien-Yung Wei; Yu-Chieh Cheng; Tzu-Liang Hsu; Chien-Rae Huang
Journal:  Int Orthop       Date:  2011-12-13       Impact factor: 3.075

2.  Korean type distal radius anatomical volar plate system: a preliminary report.

Authors:  Jeong Hwan Kim; Hyuk Jin Lee; Jihyeung Kim; Min Bom Kim; Seung Hwan Rhee; Hyun Sik Gong; Young Ho Lee; Goo Hyun Baek
Journal:  Clin Orthop Surg       Date:  2014-08-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.