Literature DB >> 20134344

Ocular and respiratory symptoms among lifeguards at a hotel indoor waterpark resort.

Bich Dang1, Lilia Chen, Charles Mueller, Kevin H Dunn, Daniel Almaguer, Jennifer L Roberts, Charles S Otto.   

Abstract

OBJECTIVES: To determine the cause of eye and respiratory irritation symptoms among lifeguards at an indoor waterpark.
METHODS: Investigators 1) performed environmental sampling for chloramine, endotoxin, and microbials; 2) administered symptom questionnaires; 3) reviewed ventilation system designs; and 4) reviewed water chemistry.
RESULTS: Airborne trichloramine concentrations were found at levels reported to cause irritation symptoms in other studies. Some endotoxin concentrations were found at levels associated with cough and fever in previous studies. Exposed lifeguards were significantly more likely to report work-related irritation symptoms than unexposed individuals. The ventilation system may not have provided sufficient air movement and distribution to adequately capture and remove air contaminants at deck level. No water microbes were detected, and water chemistry met state standards.
CONCLUSIONS: Indoor waterparks need to control water chemistry and ensure adequate air movement and distribution to control air contaminants and reduce health symptoms.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20134344     DOI: 10.1097/JOM.0b013e3181cf00d5

Source DB:  PubMed          Journal:  J Occup Environ Med        ISSN: 1076-2752            Impact factor:   2.162


  3 in total

1.  Airway irritation among indoor swimming pool personnel: trichloramine exposure, exhaled NO and protein profiling of nasal lavage fluids.

Authors:  Louise Fornander; Bijar Ghafouri; Mats Lindahl; Pål Graff
Journal:  Int Arch Occup Environ Health       Date:  2012-06-23       Impact factor: 3.015

2.  Disinfection of herbal spa pool using combined chlorine dioxide and sodium hypochlorite treatment.

Authors:  Ching-Shan Hsu; Da-Ji Huang
Journal:  Environ Monit Assess       Date:  2015-01-30       Impact factor: 2.513

3.  Respiratory health effects of exposure to low levels of airborne endotoxin - a systematic review.

Authors:  Azadèh Farokhi; Dick Heederik; Lidwien A M Smit
Journal:  Environ Health       Date:  2018-02-08       Impact factor: 5.984