Literature DB >> 20133161

A retrospective study of silicone stent placement for management of anastomotic airway complications in lung transplant recipients: short- and long-term outcomes.

Hervé Dutau1, Arnaud Cavailles, Lama Sakr, Monique Badier, Jean-Yves Gaubert, Stéphanie Boniface, Christophe Doddoli, Pascal Thomas, Martine Reynaud-Gaubert.   

Abstract

BACKGROUND: Airway anastomotic complications remain a major cause of morbidity and mortality after lung transplantation (LT). Few data are available with regard to the use of silicone stents for these airway disorders. The aim of this retrospective study was to evaluate the clinical efficacy and safety of silicone stents for such an indication.
METHODS: Data of adult lung transplant recipients who had procedures performed between January 1997 and December 2007 at our institution were reviewed retrospectively. We included patients with post-transplant airway complications who required bronchoscopic intervention with a silicone stent.
RESULTS: In 17 of 117 (14.5%) LT recipients, silicone stents were inserted at a mean time of 165 (range 5 to 360) days after surgery in order to palliate 23 anastomotic airway stenoses. Symptomatic improvement was noted in all patients, and mean forced expiratory volume in 1 second (FEV(1)) increased by 672 +/- 496 ml (p < 0.001) after stent insertion. The stent-related complication rate was 0.13/patient per month. The latter consisted of obstructive granulomas (n = 10), mucus plugging (n = 7) and migration (n = 7), which were of mild to moderate severity and were successfully managed endoscopically. Mean stent duration was 266 days (range 24 to 1,407 days). Successful stent removal was achieved in 16 of 23 cases (69.5%) without recurrence of stenosis. Overall survival was similar in patients with and without airway complications (p = 0.36).
CONCLUSIONS: Silicone stents allow clinical and lung function improvement in patients with LT-related airway complications. Stent-related complications were of mild to moderate severity, and were appropriately managed endoscopically. Permanent resolution of airway stenosis was obtained in most patients, allowing definitive stent removal without recurrence. Copyright 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20133161     DOI: 10.1016/j.healun.2009.12.011

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  12 in total

Review 1.  Stents for airway strictures: selection and results.

Authors:  Adil Ayub; Adnan M Al-Ayoubi; Faiz Y Bhora
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

Review 2.  Current status of spray cryotherapy for airway disease.

Authors:  Ryan F Moore; Deacon J Lile; Abbas E Abbas
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

Review 3.  Iatrogenic-related transplant injuries: the role of the interventional radiologist.

Authors:  Alexander Copelan; Daniel George; Baljendra Kapoor; Hahn Vu Nghiem; Jonathan M Lorenz; Brian Erly; Weiping Wang
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

4.  Airway complications have a greater impact on the outcomes of living-donor lobar lung transplantation recipients than cadaveric lung transplantation recipients.

Authors:  Seiichiro Sugimoto; Masaomi Yamane; Shinji Otani; Takeshi Kurosaki; Shuji Okahara; Yukiko Hikasa; Shinichi Toyooka; Motomu Kobayashi; Takahiro Oto
Journal:  Surg Today       Date:  2018-04-21       Impact factor: 2.549

5.  A comparative analysis of bronchial stricture after lung transplantation in recipients with and without early acute rejection.

Authors:  Anthony W Castleberry; Mathias Worni; Maragatha Kuchibhatla; Shu S Lin; Laurie D Snyder; Scott L Shofer; Scott M Palmer; Ricardo Pietrobon; R Duane Davis; Matthew G Hartwig
Journal:  Ann Thorac Surg       Date:  2013-07-18       Impact factor: 4.330

6.  Temporary placement of metallic stent could lead to long-term benefits for benign tracheobronchial stenosis.

Authors:  Guo-Wu Zhou; Hai-Dong Huang; Qin-Ying Sun; Ye Xiong; Qiang Li; Yu-Chao Dong; Wei Zhang
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

7.  Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis.

Authors:  Caroline Dahlqvist; Sebahat Ocak; Maximilien Gourdin; Anne Sophie Dincq; Laurie Putz; Jean-Paul d'Odémont
Journal:  Can Respir J       Date:  2016-09-29       Impact factor: 2.409

8.  Placement of self-expanding metallic tracheobronchial Y stent with laryngeal mask airway using conscious sedation under fluoroscopic guidance.

Authors:  Barak Pertzov; Evgeni Gershman; Shimon Izhakian; Shai M Amor; Dror Rosengarten; Mordechai R Kramer
Journal:  Thorac Cancer       Date:  2020-12-15       Impact factor: 3.500

9.  Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases.

Authors:  Benjamin Bondue; Pascal Schlossmacher; Christiane Knoop; Isabelle Etienne; Sylvie Luce; Youri Sokolow; Dimitri Leduc
Journal:  Case Rep Pulmonol       Date:  2016-03-24

10.  Airway complications after lung transplantation: benefit of a conservative bronchoscopy strategy.

Authors:  Arnaud Patoir; Antoine Luchez; Olivier Tiffet; Paul Vercherin; Renaud Grima; François Tronc; François Philit; Jean-François Mornex; Jean-Michel Vergnon; Jean-Michel Maury
Journal:  J Thorac Dis       Date:  2020-05       Impact factor: 3.005

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.