Literature DB >> 20130309

The Durom large diameter head acetabular component: early results with a large-diameter metal-on-metal bearing.

C Berton1, J Girard, N Krantz, H Migaud.   

Abstract

Implantation of a large-diameter femoral head prosthesis with a metal-on-metal bearing surface reduces the risk of dislocation, increases the range of movement, minimises the risk of impingement and, in theory, results in little wear. Between February 2004 and March 2007 we implanted 100 consecutive total hip replacements with a metal-on-metal bearing and a large femoral head into 92 patients. There were 51 men and 41 women with a mean age of 50 years (18 to 70) at the time of surgery. Outcome was assessed using the Western Ontario McMaster University osteoarthritis index and the Harris hip score as well as the Devane activity score. These all improved significantly (p < 0.0001). At the last follow-up there were no cases of dislocation, no impingement, a good range of movement and no osteolysis, but seven revisions, two for infection and five for aseptic loosening. The probability of groin pain increased if the other acetabular component inclination exceeded 50 degrees (p = 0.0007). At 4.8 years of follow-up, the projected survival of the Durom acetabular component, with revision for any reason, was 92.4% (sd 2.8) (95% confidence interval 89.6 to 95.2). The design of the component made it difficult both to orientate and seat, which when combined with a poor porous coating, produced unpredictable fixation and a low survival at five years.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20130309     DOI: 10.1302/0301-620X.92B2.22653

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

1.  Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.

Authors:  Adolph V Lombardi; Keith R Berend; Michael J Morris; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2014-11-04       Impact factor: 4.176

2.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Mid-term results of large diameter heads on cross-linked polyethylene liners in total hip replacement.

Authors:  Bhavesh Sachde; Nikunj D Maru
Journal:  J Clin Orthop Trauma       Date:  2012-10-17

4.  Correlation between groin pain and cup design of hip-resurfacing implants: a prospective study.

Authors:  Julien Girard; Erwan Pansard; Reda Ouahes; Henri Migaud; Cyril Delay; Laurent Vasseur
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

5.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

6.  Revisions of monoblock metal-on-metal THAs have high early complication rates.

Authors:  Louis S Stryker; Susan M Odum; Thomas K Fehring; Bryan D Springer
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

7.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

8.  [Revision rates in journal publications on joint prostheses with noticeably high failure rates in register data sets].

Authors:  G Labek; S Todorov; A Lübbeke-Wolff; B Haderer; S Krivanek
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

9.  Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs.

Authors:  Brett K J Kilb; Andrew P Kurmis; Michael Parry; Karen Sherwood; Paul Keown; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

10.  The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty.

Authors:  Sulaiman A Almousa; Nelson V Greidanus; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.