Literature DB >> 20129769

Two variants of occupational asthma separable by exhaled breath nitric oxide level.

Vicky C Moore1, Wasif Anees, Maritta S Jaakkola, Cedd B S G Burge, Alastair S Robertson, P Sherwood Burge.   

Abstract

UNLABELLED: Exhaled nitric oxide (FE(NO)) has been used as a marker of asthmatic inflammation in non-occupational asthma, but some asthmatics have a normal FE(NO). In this study we investigated whether, normal FE(NO) variants have less reactivity in methacholine challenge and smaller peak expiratory flow (PEF) responses than high FE(NO) variants in a group of occupational asthmatics.
METHODS: We measured FE(NO) and PD(20) in methacholine challenge in 60 workers currently exposed to occupational agents, who were referred consecutively to a specialist occupational lung disease clinic and whose serial PEF records confirmed occupational asthma. Bronchial responsiveness (PD(20) in methacholine challenge) and the degree of PEF change to occupational exposures, (measured by calculating diurnal variation and the area between curves score of the serial PEF record in Oasys), were compared between those with normal and raised FE(NO). Potential confounding factors such as smoking, atopy and inhaled corticosteroid use were adjusted for.
RESULTS: There was a significant correlation between FE(NO) and bronchial hyper-responsiveness in methacholine challenge (p = 0.011), after controlling for confounders. Reactivity to methacholine was significantly lower in the normal FE(NO) group compared to the raised FE(NO) group (p = 0.035). The two FE(NO) variants did not differ significantly according to the causal agent, the magnitude of the response in PEF to the asthmagen at work, or diurnal variation.
CONCLUSIONS: Occupational asthma patients present as two different variants based on FE(NO). The group with normal FE(NO) have less reactivity in methacholine challenge, while the PEF changes in relation to work are similar. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20129769     DOI: 10.1016/j.rmed.2010.01.007

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  2 in total

1.  Fractional exhaled nitric oxide in the interpretation of specific inhalational challenge tests for occupational asthma.

Authors:  Gareth I Walters; Vicky C Moore; Emmet E McGrath; Sherwood Burge
Journal:  Lung       Date:  2014-02       Impact factor: 2.584

2.  The value of fractional exhaled nitric oxide in occupational diseases - a systematic review.

Authors:  Marina Ruxandra Oțelea; Anne Kristin M Fell; Claudia Mariana Handra; Mathias Holm; Francesca Larese Filon; Dragan Mijakovski; Jordan Minov; Andreea Mutu; Euripides Stephanou; Zara Ann Stokholm; Sasho Stoleski; Vivi Schlünssen
Journal:  J Occup Med Toxicol       Date:  2022-07-25       Impact factor: 2.862

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.