Literature DB >> 20129576

Increased restenosis rate after implantation of drug-eluting stents in patients with elevated serum activity of matrix metalloproteinase-2 and -9.

Katharina M Katsaros1, Stefan P Kastl, Gerlinde Zorn, Gerald Maurer, Johann Wojta, Kurt Huber, Günter Christ, Walter S Speidl.   

Abstract

OBJECTIVES: Our aim was to test whether serum levels of matrix metalloproteinase (MMP)-2 and -9 are associated with the development of in-stent restenosis (ISR) after implantation of drug-eluting stents (DES).
BACKGROUND: With the introduction of DES coronary ISR could be reduced dramatically. However, it still plays a significant role, particularly after treatment of multiple, complex lesions.
METHODS: We studied 85 patients who were treated with 159 DES. Blood samples for measurement of MMP-2 and -9 antigen and activity were taken directly before and 24 h after percutaneous coronary intervention (PCI). Restenosis was evaluated at 6 to 8 months by coronary angiography.
RESULTS: During the follow-up period, 2 patients (2.4%) died of cardiovascular causes, and 12 patients developed angiographic ISR. Patients with ISR showed significantly higher serum activity of MMP-9 at baseline (p = 0.017) and of MMP-2 (p < 0.0001) and MMP-9 (p < 0.0001) after the procedure. The PCI increased serum activity of MMP-2 (p = 0.005) and MMP-9 (p = 0.008) only in patients with ISR. The restenosis rates of patients in the highest quartile of MMP-2 after and MMP-9 before and after PCI were 40.0%, 38.9%, and 42.9% compared with 6.3%, 7.7%, and 4.0% in the lower quartiles, respectively. This was independent of clinical and procedural characteristics.
CONCLUSIONS: Elevated serum activities of MMP-2 and -9 are associated with dramatically increased restenosis rates after PCI with implantation of DES. Determination of MMP levels might be useful for identification of patients who are at high risk for ISR despite implantation of DES. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20129576     DOI: 10.1016/j.jcin.2009.10.023

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  9 in total

1.  Bioreducible crosslinked polyelectrolyte complexes for MMP-2 siRNA delivery into human vascular smooth muscle cells.

Authors:  Dokyoung Lee; Dongkyu Kim; Hyejung Mok; Ji Hoon Jeong; Donghoon Choi; Sun Hwa Kim
Journal:  Pharm Res       Date:  2012-04-04       Impact factor: 4.200

Review 2.  Mechanisms of drug-eluting stent restenosis.

Authors:  Jiro Aoki; Kengo Tanabe
Journal:  Cardiovasc Interv Ther       Date:  2020-11-21

Review 3.  Restenosis after PCI. Part 1: pathophysiology and risk factors.

Authors:  J Wouter Jukema; Jeffrey J W Verschuren; Tarek A N Ahmed; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-09-13       Impact factor: 32.419

4.  Serum Levels of IL-1 β , IL-6, TGF- β , and MMP-9 in Patients Undergoing Carotid Artery Stenting and Regulation of MMP-9 in a New In Vitro Model of THP-1 Cells Activated by Stenting.

Authors:  Rongrong Zhang; Fan Jiang; Cindy Si Chen; Tianzhu Wang; Jinzhou Feng; Tao Tao; Xinyue Qin
Journal:  Mediators Inflamm       Date:  2015-05-31       Impact factor: 4.711

5.  An increase of interleukin-33 serum levels after coronary stent implantation is associated with coronary in-stent restenosis.

Authors:  Svitlana Demyanets; Ioannis Tentzeris; Rudolf Jarai; Katharina M Katsaros; Serdar Farhan; Anna Wonnerth; Thomas W Weiss; Johann Wojta; Walter S Speidl; Kurt Huber
Journal:  Cytokine       Date:  2014-03-27       Impact factor: 3.861

Review 6.  Treatment of coronary in-stent restenosis: a systematic review.

Authors:  Leos Pleva; Pavel Kukla; Ota Hlinomaz
Journal:  J Geriatr Cardiol       Date:  2018-02       Impact factor: 3.327

7.  Plasma Proteome Profiling of Patients With In-stent Restenosis by Tandem Mass Tag-Based Quantitative Proteomics Approach.

Authors:  Jingyuan Hou; Qiaoting Deng; Sudong Liu; Xiaohong Qiu; Xunwei Deng; Wei Zhong; Zhixiong Zhong
Journal:  Front Cardiovasc Med       Date:  2022-02-21

Review 8.  Hypersensitivity and in-stent restenosis in coronary stent materials.

Authors:  Wansong Hu; Jun Jiang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-15

9.  Effects of a Matrix Metalloproteinase Inhibitor-Eluting Stent on In-Stent Restenosis.

Authors:  Jian-Bo Song; Jing Shen; Jun Fan; Zhe Zhang; Zheng-Jia Yi; Shuo Bai; Xiao-Lin Mu; Liang Xiao
Journal:  Med Sci Monit       Date:  2020-03-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.