Literature DB >> 20129547

Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions).

Martin B Leon1, David E Kandzari, Eric L Eisenstein, Kevin J Anstrom, Laura Mauri, Donald E Cutlip, Eugenia Nikolsky, Charles O'Shaughnessy, Paul A Overlie, Ajay J Kirtane, Brent T McLaurin, Stuart L Solomon, John S Douglas, Jeffrey J Popma.   

Abstract

OBJECTIVES: The aim of this study was to assess, after 2 years of follow-up, the safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent (ZES) compared with a paclitaxel-eluting stent (PES) in patients with native coronary lesions.
BACKGROUND: Early drug-eluting stents were associated with a small but significant incidence of very late stent thrombosis (VLST), occurring >1 year after the index procedure. The ZES has shown encouraging results in clinical trials.
METHODS: The ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions), a randomized (1:1), single-blind, controlled trial (n = 1,548) compared ZES versus PES in patients with single de novo coronary lesions. Two-year follow-up was obtained in 96.0% of ZES and 95.4% of PES patients. The primary end point was target vessel failure (TVF), and safety end points included Academic Research Consortium-defined stent thrombosis. Economic end points analyzed included quality-adjusted survival, medical costs, and relative cost-effectiveness of ZES and PES.
RESULTS: The TVF at 2 years was similar in ZES and PES patients (11.1% vs. 13.1%, p = 0.232). There were fewer myocardial infarctions (MIs) in ZES patients (p = 0.022), due to fewer periprocedural non-Q-wave MIs and fewer late MIs between 1 and 2 years. Late MIs were associated with increased VLST (PES: 6 vs. ZES: 1; p = 0.069). Target lesion revascularization was similar comparing ZES with PES (5.9% vs. 4.6%; p = 0.295), especially in patients without planned angiographic follow-up (5.2% vs. 4.9%; p = 0.896). The cost-effectiveness of ZES and PES was similar.
CONCLUSIONS: After 2 years of follow-up, ZES demonstrated efficacy and cost-effectiveness comparable to PES, with fewer MIs and a trend toward less VLST. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20129547     DOI: 10.1016/j.jcin.2009.10.008

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  11 in total

1.  Medical devices: adapting to the comparative effectiveness landscape.

Authors:  Anita Mohandas; Kathleen A Foley
Journal:  Biotechnol Healthc       Date:  2010

Review 2.  [Second-generation DES : New, but also cost-effective?].

Authors:  F Müller-Riemenschneider; T Reinhold; S N Willich
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

Review 3.  Vascular smooth muscle cell proliferation in restenosis.

Authors:  Steven O Marx; Hana Totary-Jain; Andrew R Marks
Journal:  Circ Cardiovasc Interv       Date:  2011-02-01       Impact factor: 6.546

4.  Comparison on the efficacy of everolimus-eluting stent and zotarolimus-eluting stents in coronary heart disease between diabetic and non-diabetic patients.

Authors:  Liming Lin; Cheng Jin; Xiaoming Wei; Huiying Li; Jihong Shi; Shouling Wu; Xiaojie Yang; Xiangqian Qi
Journal:  Int J Clin Exp Med       Date:  2015-11-15

5.  A Randomized Comparison between Everolimus-Eluting Stent and Cobalt Chromium Stent in Patients with Acute ST-Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention Using Routine Intravenous Eptifibatide: The X-MAN (Xience vs. Multi-Link Stent in Acute Myocardial Infarction) Trial, A Pilot Study.

Authors:  Surya Dharma; Alexander J Wardeh; Sunarya Soerianata; Isman Firdaus; J Wouter Jukema
Journal:  Int J Angiol       Date:  2014-06

6.  Recurrent intraventricular thrombus six months after ST-elevation myocardial infarction in a diabetic man: a case report.

Authors:  Juan Lacalzada; Belén Marí; María Manuela Izquierdo; Alejandro Sánchez-Grande; Alejandro de la Rosa; Ignacio Laynez
Journal:  BMC Res Notes       Date:  2013-09-02

7.  First-generation paclitaxel- vs. second-generation zotarolimus-eluting stents in small coronary arteries: the BASKET-SMALL Pilot Study.

Authors:  Raban Jeger; Matthias Pfisterer; Otmar Pfister; Peter Rickenbacher; Michael Handke; Nicole Gilgen; Michael Coslovsky; Christoph Kaiser
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-11-17       Impact factor: 1.426

8.  Comparison of Efficacy and Safety between First and Second Generation Drug-eluting Stents in Patients with Stable Coronary Artery Disease: A Single-center Retrospective Study.

Authors:  Ru Liu; Fei Xiong; Yuan Wen; Yuan-Liang Ma; Yi Yao; Zhan Gao; Bo Xu; Yue-Jin Yang; Shu-Bin Qiao; Run-Lin Gao; Jin-Qing Yuan
Journal:  Chin Med J (Engl)       Date:  2017-07-20       Impact factor: 2.628

Review 9.  Everolimus-eluting stents in interventional cardiology.

Authors:  Jacob C Townsend; Phillip Rideout; Daniel H Steinberg
Journal:  Vasc Health Risk Manag       Date:  2012-06-27

Review 10.  Global comparative healthcare effectiveness research: evaluating sustainable programmes in low & middle resource settings.

Authors:  Rajesh Balkrishnan; Jongwha Chang; Isha Patel; Fang Yang; Sofia D Merajver
Journal:  Indian J Med Res       Date:  2013-03       Impact factor: 2.375

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.