Literature DB >> 20128535

Outcomes and patient satisfaction after presbyopic bilateral lens exchange with the ResTOR IOL in emmetropic patients.

José F Alfonso1, Luís Fernández-Vega, Beatriz Valcárcel, Teresa Ferrer-Blasco, Robert Montés-Micó.   

Abstract

PURPOSE: To assess efficacy, safety, predictability, stability, and patient satisfaction after presbyopic lens exchange in emmetropic patients.
METHODS: A prospective, nonrandomized, masked, observational case series (self-controlled) of 46 emmetropic eyes of 23 consecutive patients (age range: 50 to 60 years) after presbyopic lens exchange with bilateral AcrySof ReSTOR Natural (SN60D3) intraocular lens (IOL) (Alcon Laboratories Inc) implantation were evaluated. Mean spherical equivalent refraction (SE) was -0.04±0.14 diopters (D) (range: +0.25 to -0.25 D). Monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), distance-corrected near visual acuity (DCNVA), and patient satisfaction were recorded preoperatively and 6 months after surgery.
RESULTS: At 6 months postoperative, efficacy index at distance was 1.00. No eye lost ≥2 lines of CDVA, 5 eyes lost 1 line, 24 eyes did not change after surgery, 14 eyes gained 1 line, and 3 eyes gained 2 lines of visual acuity. Safety index at distance was 1.03. All eyes had a manifest SE within ±0.50 D of emmetropia. Mean postoperative SE was +0.14±0.22 D (range: -0.25 to +0.37 D). No eye lost >2 lines of DCNVA, 1 eye lost 2 lines, 3 eyes lost 1 line, 34 eyes did not change after surgery, and 8 eyes gained 1 line of visual acuity. Uncorrected near visual acuity was 0.95±0.07. Safety and efficacy indexes at near were 1.01 and 1.03, respectively. A patient satisfaction questionnaire showed that patients had a high level of satisfaction after presbyopic lens exchange surgery.
CONCLUSIONS: Presbyopic lens exchange with implantation of the ReSTOR multifocal IOL in emmetropic eyes is an effective and safe procedure for presbyopia correction. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20128535     DOI: 10.3928/1081597X-20100114-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation.

Authors:  José F Alfonso; Luis Fernández-Vega; Susana Ortí; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-16       Impact factor: 3.117

2.  Ultrashort-pulse lasers treating the crystalline lens: will they cause vision-threatening cataract? (An American Ophthalmological Society thesis).

Authors:  Ronald R Krueger; Harvey Uy; Jared McDonald; Keith Edwards
Journal:  Trans Am Ophthalmol Soc       Date:  2012-12

3.  Visual outcomes and patient satisfaction after refractive lens exchange with a single-piece diffractive multifocal intraocular lens.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2014-11-23       Impact factor: 1.909

4.  Visual Outcomes, Quality of Vision, and Quality of Life of Diffractive Multifocal Intraocular Lens Implantation after Myopic Laser In Situ Keratomileusis: A Prospective, Observational Case Series.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

Review 5.  Optimizing outcomes with multifocal intraocular lenses.

Authors:  Gitansha Shreyas Sachdev; Mahipal Sachdev
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

6.  Monovision LASIK in emmetropic presbyopic patients.

Authors:  Michelle Y Peng; Stephen Hannan; David Teenan; Steven J Schallhorn; Julie M Schallhorn
Journal:  Clin Ophthalmol       Date:  2018-09-04

7.  Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens.

Authors:  José F Alfonso; Andrés Fernández-Vega-Cueto; Belén Alfonso-Bartolozzi; Ignacio Rodríguez-Uña; Robert Montés-Micó
Journal:  Clin Ophthalmol       Date:  2019-11-20
  7 in total