F Albert1, S G Anderson, G A Anderson, S M Betts, D J Gibson, C A Hagmann, J Hall, M S Johnson, M J Messerly, V A Semenov, M Y Shverdin, A M Tremaine, F V Hartemann, C W Siders, D P McNabb, C P J Barty.
Abstract
What we believe to be the first demonstration of isotope-specific detection of a low-Z and low density object shielded by a high-Z and high-density material using monoenergetic gamma rays is reported. The isotope-specific detection of LiH shielded by Pb and Al is accomplished using the nuclear resonance fluorescence line of L7i at 478 keV. Resonant photons are produced via laser-based Compton scattering. The detection techniques are general, and the confidence level obtained is shown to be superior to that yielded by conventional x-ray and gamma-ray techniques in these situations.Entities:
Year: 2010 PMID: 20125719 DOI: 10.1364/OL.35.000354