Literature DB >> 20123893

Factors influencing uncertainty in measurement of electric fields close to the body in personal RF dosimetry.

S Iskra1, R McKenzie, I Cosic.   

Abstract

This paper provides an insight into factors that can influence uncertainty in measurements at 900 MHz of electric fields close to the body for use in personal dosimetry. Computational simulations using the finite difference time domain method were used to determine the total electric field near the surface of the torso of heterogeneous (adult and child) human body models for a set of exposure scenarios that simulated both spatially constant and randomly varying incident fields. Modelling has shown that a properly responding isotropic electric field dosemeter mounted between 10 and 50 mm of the torso will on average underestimate the incident field strength by up to 6.45 dB. In the worst case (i.e. spatially constant field), the standard deviation or uncertainty reached 6.42 dB. Uncertainty was reduced to <2.17 dB by combining the simultaneous outputs of a pair of body-worn dosemeters (mounted front and rear of torso).

Entities:  

Mesh:

Year:  2010        PMID: 20123893     DOI: 10.1093/rpd/ncp309

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  The role of the location of personal exposimeters on the human body in their use for assessing exposure to the electromagnetic field in the radiofrequency range 98-2450 MHz and compliance analysis: evaluation by virtual measurements.

Authors:  Krzysztof Gryz; Patryk Zradziński; Jolanta Karpowicz
Journal:  Biomed Res Int       Date:  2015-03-24       Impact factor: 3.411

2.  Radiofrequency Exposure Amongst Employees of Mobile Network Operators and Broadcasters.

Authors:  Ian Litchfield; Martie van Tongeren; Tom Sorahan
Journal:  Radiat Prot Dosimetry       Date:  2017-06-15       Impact factor: 0.972

Review 3.  EMF monitoring-concepts, activities, gaps and options.

Authors:  Gregor Dürrenberger; Jürg Fröhlich; Martin Röösli; Mats-Olof Mattsson
Journal:  Int J Environ Res Public Health       Date:  2014-09-11       Impact factor: 3.390

4.  A Personal, Distributed Exposimeter: Procedure for Design, Calibration, Validation, and Application.

Authors:  Arno Thielens; Peter Vanveerdeghem; Patrick Van Torre; Stephanie Gängler; Martin Röösli; Hendrik Rogier; Luc Martens; Wout Joseph
Journal:  Sensors (Basel)       Date:  2016-02-01       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.