Endovascular aortic aneurysm repair with the Endurant stent-graft: early and 1-year results from a European multicenter experience.

Giovanni Torsello1, Nicola Troisi, Jörg Tessarek, Giovanni Federico Torsello, Walter Dorigo, Raffaele Pulli, Carlo Pratesi.   

Abstract

PURPOSE: To assess preliminary results of the Endurant stent-graft, which was developed to treat patients with abdominal aortic aneurysms (AAAs) and challenging aortoiliac anatomy.
MATERIALS AND METHODS: From November 2007 to October 2008, 45 patients with AAAs were treated with the Endurant stent-graft in three European vascular centers. Thirty-eight of the 45 patients (84%) had a hostile anatomy of the proximal neck. Early (30 days), early midterm (6 months), and late midterm (1 year) results were analyzed in terms of technical success, clinical success, morbidity, and mortality.
RESULTS: Intraoperative immediate technical and clinical success was achieved in all cases. At completion angiography, a type II endoleak was detected in seven of the 45 patients (16%) and an iliac limb stenosis was diagnosed and successfully treated in five (11%). At discharge, computed tomography demonstrated a type I endoleak in one of the 45 patients (2.2%). At 30 days, a graft limb thrombosis was diagnosed (2.2%) and successfully treated. The 30-day overall technical and clinical success rates were 97.8% (44/45 cases) and 95.6% (43/45 cases), respectively. During follow-up (mean duration, 8 months; range, 5-16 months), the type I endoleak was successfully treated with an aortic extension. Estimated freedom from type I or III endoleak and repeat intervention at 1 year was 97.8% (44/45 cases) and 93.3% (42/45 cases), respectively.
CONCLUSIONS: The initial experience shows that the Endurant stent-graft appears to be effective in endovascular repair of AAAs in patients with hostile aortoiliac anatomy. This graft permits a broader group of patients to be treated with endovascular aneurysm repair; however, further studies are needed to evaluate the long-term results.

Entities:  

Mesh:

Year:  2010        PMID: 20123193     DOI: 10.1016/j.jvir.2009.09.021

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  2 in total

1.  The Endurant Stent Graft System: 15-month follow-up report in patients with challenging abdominal aortic anatomies.

Authors:  Alexander Hyhlik-Dürr; Tim F Weber; Drossos Kotelis; Fabian Rengier; Johannes Gahlen; Stefanie Böck; Jürgen Köhler; Christoph-M Ratusinski; Dittmar Böckler
Journal:  Langenbecks Arch Surg       Date:  2011-05-25       Impact factor: 3.445

2.  Troubleshooting techniques for the Endurant™ device in endovascular aortic aneurysm repair.

Authors:  George S Georgiadis; George A Antoniou; George Trellopoulos; Efstratios I Georgakarakos; Christos Argyriou; Miltos K Lazarides
Journal:  Cardiovasc J Afr       Date:  2014-09-02       Impact factor: 1.167

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.