Literature DB >> 20122747

6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT.

Zheng Chang1, Zhiheng Wang, Jinli Ma, Jennifer C O'Daniel, John Kirkpatrick, Fang-Fang Yin.   

Abstract

PURPOSE: To investigate setup discrepancies measured with ExacTrac X-ray 6 degree-of-freedom (6D) and cone-beam computed tomography (CBCT) for patients under treatments of stereotactic body radiation therapy (SBRT).
MATERIALS AND METHODS: In this work, phantom and patient studies were performed. In the phantom studies, an anthropomorphic phantom was placed with pre-defined positions, and imaged with ExacTrac X-ray 6D and CBCT to test the accuracy of the imaging systems. In the patient studies, 16 spinal SBRT patient cases were retrospectively analyzed. The patients were initially positioned in customized immobilization cradles and then aligned with ExacTrac X-ray 6D and CBCT. The setup discrepancies were computed and quantitatively analyzed.
RESULTS: This study indicates modest discrepancies between ExacTrac X-ray 6D and CBCT with spinal SBRT. The phantom experiments showed that translational and rotational discrepancies in root-mean-square (RMS) between ExacTrac X-ray 6D and CBCT were, respectively, <1.0mm and <1 degrees . In the retrospective patient studies, translational and rotational discrepancies in RMS between ExacTrac X-ray 6D and CBCT were <2.0mm and <1.5 degrees .
CONCLUSIONS: ExacTrac X-ray 6D represents a potential alternative to CBCT; however, pre-caution should be taken when only ExacTrac X-ray 6D is used to guide SBRT with small setup margins. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20122747     DOI: 10.1016/j.radonc.2009.12.036

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  22 in total

Review 1.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

2.  A Relationship Between Cervical Vertebrae Twisting and Cranial Angle in Head and Neck Radiotherapy.

Authors:  Takahiro Aoyama; Hidetoshi Shimizu; Koji Sasaki; Mio Ando; Naoki Kaneda; Hiroyuki Tachibana; Kojiro Suzuki; Takeshi Kodaira
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

3.  Prospective validation of treatment accuracy using implanted fiducial markers for spinal stereotactic body radiation therapy.

Authors:  David C Weksberg; James N Yang; Alda L Tam; Jing Li; Xin A Wang; Zhongxiang Zhao; Stephen E McRae; Stephen H Settle; Laurence D Rhines; Eric L Chang; Paul D Brown; Amol J Ghia
Journal:  J Radiosurg SBRT       Date:  2016

4.  Toward understanding deep learning classification of anatomic sites: lessons from the development of a CBCT projection classifier.

Authors:  Juan P Cruz-Bastida; Erik Pearson; Hania Al-Hallaq
Journal:  J Med Imaging (Bellingham)       Date:  2022-07-25

5.  Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy.

Authors:  David Y Hu; Yiwen Xu; Yu-Hui Chen; Marjan Khosravi; Yulia Lyatskaya; Jeremy S Bredfeldt; Fred L Hacker; Tracy A Balboni; Alexander Spektor; Daniel Cagney; Raymond Mak; Mai Anh Huynh
Journal:  Adv Radiat Oncol       Date:  2022-04-08

6.  Digital reconstructed radiography with multiple color image overlay for image-guided radiotherapy.

Authors:  Shinichi Yoshino; Kentaro Miki; Kozo Sakata; Yuko Nakayama; Kouichi Shibayama; Shinichiro Mori
Journal:  J Radiat Res       Date:  2015-02-11       Impact factor: 2.724

7.  Development of fast patient position verification software using 2D-3D image registration and its clinical experience.

Authors:  Shinichiro Mori; Motoki Kumagai; Kentaro Miki; Riki Fukuhara; Hideaki Haneishi
Journal:  J Radiat Res       Date:  2015-06-16       Impact factor: 2.724

8.  First clinical experience in carbon ion scanning beam therapy: retrospective analysis of patient positional accuracy.

Authors:  Shinichiro Mori; Kouichi Shibayama; Katsuyuki Tanimoto; Motoki Kumagai; Yuka Matsuzaki; Takuji Furukawa; Taku Inaniwa; Toshiyuki Shirai; Koji Noda; Hiroshi Tsuji; Tadashi Kamada
Journal:  J Radiat Res       Date:  2012-09       Impact factor: 2.724

9.  Spine Stereotactic Body Radiation Therapy Residual Setup Errors and Intra-Fraction Motion Using the Stereotactic X-Ray Image Guidance Verification System.

Authors:  Kosj Yamoah; Nicholas G Zaorsky; Joshua Siglin; Wenyin Shi; Maria Werner-Wasik; David W Andrews; Adam P Dicker; Voichita Bar-Ad; Haisong Liu
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2014-02

10.  Development of an automatic evaluation method for patient positioning error.

Authors:  Yoshiki Kubota; Mutsumi Tashiro; Ayaka Shinohara; Satoshi Abe; Saki Souda; Ryosuke Okada; Takayoshi Ishii; Tatsuaki Kanai; Tatsuya Ohno; Takashi Nakano
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102