Preoxygenation by 8 deep breaths in 60 seconds using the Mapleson A (Magill), the circle system, or the Mapleson D system.

Samar K Taha1, Mohamad F El-Khatib, Sahar M Siddik-Sayyid, Faraj W Abdallah, Carla M Dagher, Jules-Marie A Chehade, Anis S Baraka.   

Abstract

STUDY
OBJECTIVE: To investigate the efficacy of preoxygenation by eight deep breaths in 60 seconds with the Mapleson A (Magill) system, the circle anesthesia system, or the Mapleson D system at an oxygen flow of 5 L/min or 10 L/min.
DESIGN: Randomized, clinical study.
SETTING: Operating room of a university hospital.
SUBJECTS: 10 healthy volunteers.
INTERVENTIONS: Volunteers underwent 6 preoxygenation trials consisting of 8 deep breaths in 60 seconds using the Mapleson A, Mapleson D, and the circle anesthesia systems at an oxygen flow of 5 L/min and 10 L/min. MEASUREMENTS: Fractional end-tidal oxygen concentration (F(ET)O(2)) was measured at 15-second intervals during preoxygenation.
RESULTS: At an oxygen flow of 10 L/min, mean F(ET)O(2) values at 60 seconds of preoxygenation were comparable among the Mapleson A, Mapleson D, and the circle anesthesia systems (87 +/- 2.1%, 87 +/- 1.6%, 87 +/- 1.6%, respectively). Using an oxygen flow of 5 L/min, mean F(ET)O(2) values at 60 seconds were similar among the Mapleson A, Mapleson D, and circle anesthesia systems (74 +/- 4.1%, 75 +/- 2.6%, 74 +/- 4.4%, respectively); however, they were significantly lower than the corresponding values achieved at an oxygen flow of 10 L/min.
CONCLUSIONS: The 8-deep-breaths in 60 seconds technique at an oxygen flow of 10 L/min can achieve adequate preoxygenation with the Mapleson A (Magill), Mapleson D, and circle anesthesia systems. Suboptimal preoxygenation is obtained with the three systems when the oxygen flow used is 5 L/min.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20122589     DOI: 10.1016/j.jclinane.2009.01.013

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Effect of high fresh gas flow and pattern of breathing on rapid preoxygenation.

Authors:  Gincy Mathew; M Manjuladevi; Nayanthara Joachim; Apoorwa N Kothari
Journal:  Indian J Anaesth       Date:  2022-03-24

2.  Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.

Authors:  C Frerk; V S Mitchell; A F McNarry; C Mendonca; R Bhagrath; A Patel; E P O'Sullivan; N M Woodall; I Ahmad
Journal:  Br J Anaesth       Date:  2015-11-10       Impact factor: 9.166

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.