Literature DB >> 20118702

Ultrasonography versus chest radiography after chest tube removal for the detection of pneumothorax.

Sandra Saucier1, Carrie Motyka, Keith Killu.   

Abstract

BACKGROUND: Bedside ultrasound technology is an innovative, cost-effective, safe, and reproducible method used to make efficient decisions that directly affect the care of critical care patients.
PURPOSE: To validate the use of ultrasound technology when compared with the use of standard chest radiography for the detection of pneumothorax following chest tube removal.
METHODS: A prospective observational comparison study of 50 cardiothoracic patients with surgically placed pleural chest tubes was conducted. The accuracy of bedside ultrasound technology was compared with standard chest radiography to detect pneumothorax.
RESULTS: The sample kappa statistic was 1.000, indicating a perfect agreement between bedside ultrasonography and chest radiography in the detection of pneumothorax. Completion of the bedside ultrasound procedure took significantly less time than chest radiography.
CONCLUSIONS: Bedside ultrasound technology is as accurate as chest radiography in detecting pneumothorax following chest tube removal and can save institutions' time and money.

Entities:  

Mesh:

Year:  2010        PMID: 20118702     DOI: 10.1097/NCI.0b013e3181c8013a

Source DB:  PubMed          Journal:  AACN Adv Crit Care        ISSN: 1559-7768


  2 in total

1.  Extended-FAST plus MDCT in pneumothorax diagnosis of major trauma: time to revisit ATLS imaging approach?

Authors:  Stefania Ianniello; Claudia Lucia Piccolo; Margherita Trinci; Claudio A Ajmone Cat; Vittorio Miele
Journal:  J Ultrasound       Date:  2019-11-04

2.  The feasibility of nurse practitioner-performed, telementored lung telesonography with remote physician guidance - 'a remote virtual mentor'.

Authors:  Nancy Biegler; Paul B McBeth; Corina Tiruta; Douglas R Hamilton; Zhengwen Xiao; Innes Crawford; Martha Tevez-Molina; Nat Miletic; Chad G Ball; Linping Pian; Andrew W Kirkpatrick
Journal:  Crit Ultrasound J       Date:  2013-06-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.