Literature DB >> 20117970

Clinical evaluation of posterior all-ceramic FPDs (Cercon): a prospective clinical pilot study.

Mitsuyoshi Tsumita1, Yuji Kokubo, Chikahiro Ohkubo, Satoe Sakurai, Shunji Fukushima.   

Abstract

PURPOSE: This study prospectively evaluated the clinical performance of posterior zirconium-oxide-based all-ceramic fixed partial dentures (FPDs).
METHODS: Forty-two abutments of 21 Cercon FPDs were fitted in 20 patients at the Tsurumi University Dental Hospital from August 2005 to August 2006. The performance of these FPDs was evaluated using the California Dental Association (CDA) quality assessment system at baseline and at all follow-up examinations.
RESULTS: All FPDs were examined after a mean observation period of 28.1 (+/-3.4) months. During the observation period, no fracturing of FPDs was seen. All of the FPDs examined were rated as satisfactory with regard to all factors at the follow-up examinations based on the CDA quality assessment criteria.
CONCLUSION: Within the limitations of this short-term clinical study, no core framework fractures were seen. According to the CDA criteria, 100% of the FPDs were rated as satisfactory during this observation period.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20117970     DOI: 10.1016/j.jpor.2010.01.001

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  7 in total

1.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

2.  Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses.

Authors:  Roberto Sorrentino; Giorgio De Simone; Stefano Tetè; Simona Russo; Fernando Zarone
Journal:  Clin Oral Investig       Date:  2011-06-11       Impact factor: 3.573

Review 3.  Do tooth-supported zirconia restorations present more technical failures related to fracture or loss of retention? Systematic review and meta-analysis.

Authors:  Carla Castiglia Gonzaga; Paula Pontes Garcia; Letícia Maíra Wambier; Fernanda Harumi Oku Prochnow; Luciano Madeira; Paulo Francisco Cesar
Journal:  Clin Oral Investig       Date:  2022-06-04       Impact factor: 3.606

Review 4.  Dental Ceramics for Restoration and Metal Veneering.

Authors:  Yu Zhang; J Robert Kelly
Journal:  Dent Clin North Am       Date:  2017-10

5.  The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.

Authors:  Seung-Ryong Ha; Sung-Hun Kim; Jung-Suk Han; Seung-Hyun Yoo; Se-Chul Jeong; Jai-Bong Lee; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

6.  Clinical performance and failures of zirconia-based fixed partial dentures: a review literature.

Authors:  Premwara Triwatana; Noppavan Nagaviroj; Chantana Tulapornchai
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

7.  Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth.

Authors:  Martin Rosentritt; Frederik Schumann; Stephanie Krifka; Verena Preis
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.