Literature DB >> 20117324

Assessing variability and comparing short-term biomarkers of styrene exposure using a repeated measurements approach.

S Fustinoni1, P Manini, L Campo, G De Palma, R Andreoli, A Mutti, P A Bertazzi, S M Rappaport.   

Abstract

The aim of this work is to compare several short-term biomarkers of styrene exposure, namely urinary styrene (StyU), mercapturic acids (M1+M2), mandelic acid (MA), phenylglyoxylic acid (PGA), phenylglycine (PHG), and 4-vinylphenol conjugates (VP), for use as biomarkers of exposure in epidemiologic studies. A repeated measurements protocol (typically 4 measurements per worker over 6 weeks) was applied to measure airborne styrene (StyA) and urinary biomarkers in 10 varnish and 8 fiberglass reinforced plastic workers. Estimated geometric mean personal exposures to StyA were 2.96mg/m(3) in varnish workers and 15.7mg/m(3) in plastic workers. The corresponding levels of StyU, M1+M2, MA, PGA, MA+PGA, PHG and VP were 5.13microg/L, 0.111, 38.2, 22.7, 62.6, 0.978, and 3.97mg/g creatinine in varnish workers and 8.38microg/L, 0.303, 146, 83.4, 232, 2.85 and 3.97mg/g creatinine in plastic workers. Within-worker (sigma(wY)(2)) and between-worker (sigma(bY)(2)) variance components were estimated from the log-transformed data as were the corresponding fold ranges containing 95% of the respective lognormal distributions of daily levels ((w)R(0.95)) and subject-specific mean levels ((b)R(0.95)). Estimates of (w)R(0.95) (range: 4-26) were generally smaller than those of (b)R(0.95) (range: 5-790) for both environmental and biological markers; this indicates that exposures varied much more between workers than within workers in these groups. Since attenuation bias in an estimated exposure-response relationship increases with the variance ratio lambda=sigma(wY)(2)/sigma(bY)(2), we estimated values of lambda for all exposure measures in our study. Values of lambda were typically much less than one (median=0.220) and ranged from 0.089 for M1+M2 in plastic workers to 1.38 for PHG in varnish workers. Since values of lambda were 0.147 and 0.271 for StyA in varnish workers and plastic workers, respectively, compared to 0.178 and 0.210 for MA in the same groups, our results suggest that either air measurements or conventional biomarker measurements (urinary MA) would be comparable surrogates for individual exposures in epidemiologic studies. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20117324     DOI: 10.1016/j.toxlet.2009.02.004

Source DB:  PubMed          Journal:  Toxicol Lett        ISSN: 0378-4274            Impact factor:   4.372


  3 in total

1.  Evaluation of occupational exposure: comparison of biological and environmental variabilities using physiologically based toxicokinetic modeling.

Authors:  G Truchon; R Tardif; G Charest-Tardif; A de Batz; P O Droz
Journal:  Int Arch Occup Environ Health       Date:  2012-03-13       Impact factor: 3.015

2.  Biomarker variance component estimation for exposure surrogate selection and toxicokinetic inference.

Authors:  Jon R Sobus; Joachim D Pleil; Michael D McClean; Robert F Herrick; Stephen M Rappaport
Journal:  Toxicol Lett       Date:  2010-09-22       Impact factor: 4.372

3.  The Relationship Between Widespread Pollution Exposure and Oxidized Products of Nucleic Acids in Seminal Plasma and Urine in Males Attending a Fertility Center.

Authors:  Diana Poli; Roberta Andreoli; Lucia Moscato; Giovanna Pelà; Giuseppe de Palma; Delia Cavallo; Marta Petyx; Giorgio Pelosi; Massimo Corradi; Matteo Goldoni
Journal:  Int J Environ Res Public Health       Date:  2020-03-13       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.