I Tanoubi1, P Drolet, L P Fortier, F Donati. 1. Département d'anesthésie, hôpital Maisonneuve-Rosemont, centre hospitalier, université de Montréal, 5415, boulevard de l'Assomption, Montréal, QC, Canada, H1T 2M4. i.tanoubi@umontreal.ca
Abstract
OBJECTIVE: Applying an inspiratory support (AI) and a positive end expiratory pressure (PEP) could increase the effectiveness of the preoxygenation. STUDY DESIGN: This randomized double blinded controlled study compares the impact on the expiratory oxygen fraction (FEO(2)) of two levels of AI with PEP to a traditional preoxygenation. PATIENTS AND METHODS: Twenty healthy volunteers were studied. The criteria of exclusion were a body mass index >30, the presence of beard or moustache and the claustrophobia. Each subject went through three modes of preoxygenation during 3 minutes each in a random order: 1-spontaneous ventilation (VS), 2-preoxygenation with AI with 4 cmH(2)O/PEP 4 cmH(2)O (AI-4/PEP-4), 3-preoxygenation with AI with 6 cmH(2)O/PEP 4 cmH(2)O (AI-6/PEP-4). Subject's tolerance and leaks were also noted. RESULTS: The FEO(2) at the end of the 3 minutes of preoxygenation was higher (p<0,001) with AI-4/PEP-4 (94+/-3%) and AI-6/PEP-4 (94+/-4%) than with technique VS (89+/-6%). One hundred percent and 90% of the participants reached one FEO(2)=90% with AI-4/PEP-4 and AI-6/PEP-4 respectively vs 65% with VS (p=0.0013). The participants tolerated better the VS and the AI-4/PEP-4 than the AI-6/PEP-4. More leaks were noted with the AI-6/PEP-4 than with the VS and the AI-4/PEP-4. CONCLUSION: This study shows applying AI plus PEP during preoxygenation improves its effectiveness in the healthy subjects. It also suggests that, in a population of healthy volunteers, combination AI-4/PEP-4 is preferable to AI-6/PEP-4 because so effective, but better tolerated. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.
RCT Entities:
OBJECTIVE: Applying an inspiratory support (AI) and a positive end expiratory pressure (PEP) could increase the effectiveness of the preoxygenation. STUDY DESIGN: This randomized double blinded controlled study compares the impact on the expiratory oxygen fraction (FEO(2)) of two levels of AI with PEP to a traditional preoxygenation. PATIENTS AND METHODS: Twenty healthy volunteers were studied. The criteria of exclusion were a body mass index >30, the presence of beard or moustache and the claustrophobia. Each subject went through three modes of preoxygenation during 3 minutes each in a random order: 1-spontaneous ventilation (VS), 2-preoxygenation with AI with 4 cmH(2)O/PEP 4 cmH(2)O (AI-4/PEP-4), 3-preoxygenation with AI with 6 cmH(2)O/PEP 4 cmH(2)O (AI-6/PEP-4). Subject's tolerance and leaks were also noted. RESULTS: The FEO(2) at the end of the 3 minutes of preoxygenation was higher (p<0,001) with AI-4/PEP-4 (94+/-3%) and AI-6/PEP-4 (94+/-4%) than with technique VS (89+/-6%). One hundred percent and 90% of the participants reached one FEO(2)=90% with AI-4/PEP-4 and AI-6/PEP-4 respectively vs 65% with VS (p=0.0013). The participants tolerated better the VS and the AI-4/PEP-4 than the AI-6/PEP-4. More leaks were noted with the AI-6/PEP-4 than with the VS and the AI-4/PEP-4. CONCLUSION: This study shows applying AI plus PEP during preoxygenation improves its effectiveness in the healthy subjects. It also suggests that, in a population of healthy volunteers, combination AI-4/PEP-4 is preferable to AI-6/PEP-4 because so effective, but better tolerated. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.