Literature DB >> 20116277

Detection of neutralizing interleukin-17 antibodies in autoimmune polyendocrinopathy syndrome-1 (APS-1) patients using a novel non-cell based electrochemiluminescence assay.

Isabelle Cludts1, Anthony Meager, Robin Thorpe, Meenu Wadhwa.   

Abstract

Antibodies that neutralize interleukin-17A (IL-17A) are classically detected and quantified using cell-based assays. However, these assays are cumbersome, inherently variable and often susceptible to interference by the matrix of test samples, such as human sera. Since neutralizing antibodies block binding of IL-17A to its cell surface receptor, IL-17R, we used antibody inhibition of IL-17A binding to recombinant IL-17R/Fc fusion protein in an electrochemiluminescence (ECL) platform to develop a novel, non-cell based ligand binding assay that functionally mimics cell-based neutralization assays. Using specific polyclonal antisera and a panel of sera containing neutralizing anti-IL-17A autoantibodies from patients with autoimmune polyendocrinopathy syndrome-1, we have shown that this assay generates neutralizing titers that correlate well with those found using cell-based assays. The assay is simple to perform, reliable, and more accessible to clinical laboratories than cell-based assays. In principle, the assay methodology could be extended to detection of neutralizing antibodies to biotherapeutics for assessment of unwanted immunogenicity of biotherapeutic products. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20116277     DOI: 10.1016/j.cyto.2010.01.001

Source DB:  PubMed          Journal:  Cytokine        ISSN: 1043-4666            Impact factor:   3.861


  3 in total

1.  Ultrasensitive Analysis of Binding Affinity of HIV Receptor and Neutralizing Antibody Using Solution-Phase Electrochemiluminescence Assay.

Authors:  Xiao-Hong Nancy Xu; Zhaoyang Wen; William J Brownlow
Journal:  J Electroanal Chem (Lausanne)       Date:  2013-01-01       Impact factor: 4.464

2.  Detection of Infertility-related Neutralizing Antibodies with a Cell-free Microfluidic Method.

Authors:  Klaus Eyer; Katharina Root; Pascal E Verboket; Petra S Dittrich
Journal:  Sci Rep       Date:  2015-11-20       Impact factor: 4.379

3.  Eight-Channel AC Magnetosusceptometer of Magnetic Nanoparticles for High-Throughput and Ultra-High-Sensitivity Immunoassay.

Authors:  Jen-Jie Chieh; Wen-Chun Wei; Shu-Hsien Liao; Hsin-Hsein Chen; Yen-Fu Lee; Feng-Chun Lin; Ming-Hsien Chiang; Ming-Jang Chiu; Herng-Er Horng; Shieh-Yueh Yang
Journal:  Sensors (Basel)       Date:  2018-03-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.