Literature DB >> 20109492

Gain of the human dura in vivo and its effects on invasive brain signal feature detection.

Aldemar Torres Valderrama1, Robert Oostenveld, Mariska J Vansteensel, Geertjan M Huiskamp, Nicolas Franciscus Ramsey.   

Abstract

Invasive brain signal recordings generally rely on bioelectrodes implanted on the cortex underneath the dura. Subdural recordings have strong advantages in terms of bandwidth, spatial resolution and signal quality. However, subdural electrodes also have the drawback of compromising the long-term stability of such implants and heighten the risk of infection. Epidurally implanted electrodes might provide a viable alternative to subdural electrodes, offering a compromise between signal quality and invasiveness. Determining the feasibility of epidural electrode implantation for e.g., clinical research, brain-computer interfacing (BCI) and cognitive experiments, requires the characterization of the electrical properties of the dura, and its effect on signal feature detection. In this paper we report measurements of brain signal attenuation by the human dura in vivo. In addition, we use signal detection theory to study how the presence of the dura between the sources and the recording electrodes affects signal power features in motor BCI experiments. For noise levels typical of clinical brain signal recording equipment, we observed no detrimental effects on signal feature detection due to the dura. Subdural recordings were found to be more robust with respect to increased instrumentation noise level as compared to their epidural counterpart nonetheless. Our findings suggest that epidural electrode implantation is a viable alternative to subdural implants from the feature detection viewpoint. Copyright (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20109492     DOI: 10.1016/j.jneumeth.2010.01.019

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  9 in total

1.  Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity.

Authors:  Thomas J Oxley; Nicholas L Opie; Sam E John; Gil S Rind; Stephen M Ronayne; Tracey L Wheeler; Jack W Judy; Alan J McDonald; Anthony Dornom; Timothy J H Lovell; Christopher Steward; David J Garrett; Bradford A Moffat; Elaine H Lui; Nawaf Yassi; Bruce C V Campbell; Yan T Wong; Kate E Fox; Ewan S Nurse; Iwan E Bennett; Sébastien H Bauquier; Kishan A Liyanage; Nicole R van der Nagel; Piero Perucca; Arman Ahnood; Katherine P Gill; Bernard Yan; Leonid Churilov; Christopher R French; Patricia M Desmond; Malcolm K Horne; Lynette Kiers; Steven Prawer; Stephen M Davis; Anthony N Burkitt; Peter J Mitchell; David B Grayden; Clive N May; Terence J O'Brien
Journal:  Nat Biotechnol       Date:  2016-02-08       Impact factor: 54.908

2.  Characterization of the effects of the human dura on macro- and micro-electrocorticographic recordings.

Authors:  David T Bundy; Erik Zellmer; Charles M Gaona; Mohit Sharma; Nicholas Szrama; Carl Hacker; Zachary V Freudenburg; Amy Daitch; Daniel W Moran; Eric C Leuthardt
Journal:  J Neural Eng       Date:  2014-02       Impact factor: 5.379

Review 3.  Physiological properties of brain-machine interface input signals.

Authors:  Marc W Slutzky; Robert D Flint
Journal:  J Neurophysiol       Date:  2017-06-14       Impact factor: 2.714

4.  Workshops of the Fifth International Brain-Computer Interface Meeting: Defining the Future.

Authors:  Jane E Huggins; Christoph Guger; Brendan Allison; Charles W Anderson; Aaron Batista; Anne-Marie A-M Brouwer; Clemens Brunner; Ricardo Chavarriaga; Melanie Fried-Oken; Aysegul Gunduz; Disha Gupta; Andrea Kübler; Robert Leeb; Fabien Lotte; Lee E Miller; Gernot Müller-Putz; Tomasz Rutkowski; Michael Tangermann; David Edward Thompson
Journal:  Brain Comput Interfaces (Abingdon)       Date:  2014-01

5.  Identifying the Attended Speaker Using Electrocorticographic (ECoG) Signals.

Authors:  K Dijkstra; P Brunner; A Gunduz; W Coon; A L Ritaccio; J Farquhar; G Schalk
Journal:  Brain Comput Interfaces (Abingdon)       Date:  2015-08-26

6.  Monkey V1 epidural field potentials provide detailed information about stimulus location, size, shape, and color.

Authors:  Benjamin Fischer; Detlef Wegener
Journal:  Commun Biol       Date:  2021-06-07

7.  Rapid Communication with a "P300" Matrix Speller Using Electrocorticographic Signals (ECoG).

Authors:  Peter Brunner; Anthony L Ritaccio; Joseph F Emrich; Horst Bischof; Gerwin Schalk
Journal:  Front Neurosci       Date:  2011-02-07       Impact factor: 4.677

8.  Epidural electrocorticography for monitoring of arousal in locked-in state.

Authors:  Suzanne Martens; Michael Bensch; Sebastian Halder; Jeremy Hill; Femke Nijboer; Ander Ramos-Murguialday; Bernhard Schoelkopf; Niels Birbaumer; Alireza Gharabaghi
Journal:  Front Hum Neurosci       Date:  2014-10-21       Impact factor: 3.169

Review 9.  Neural coding for effective rehabilitation.

Authors:  Xiaoling Hu; Yiwen Wang; Ting Zhao; Aysegul Gunduz
Journal:  Biomed Res Int       Date:  2014-09-02       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.