Technical challenges associated with the radiolabeling of monoclonal antibodies utilizing short-lived, positron emitting radionuclides.

R Finn1, N K Cheung, C Divgi, J St Germain, M Graham, K Pentlow, S M Larson.   

Abstract

Many factors, both physical and chemical, affect the radiolabeling of a chemical compound. These factors add a new dimension of complexity when the labeling of monoclonal antibodies is attempted with short-lived, positron emitting radionuclides. A lack of appreciation for the unique chemical separations associated with the radionuclide incorporated into the synthetic precursor can often lead to unexpected or non-reproducible results.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2010313     DOI: 10.1016/0883-2897(91)90040-r

Source DB:  PubMed          Journal:  Int J Rad Appl Instrum B        ISSN: 0883-2897


  5 in total

1.  Applicability of short-lived radiometallic nuclide for high sensitivity two-site "sandwich" immunoradiometric assay: human growth hormone assay.

Authors:  K Horiuchi; L H Lin; Y Fujibayashi; V C Borghi; A Yokoyama
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

2.  Development of a method to measure kinetics of radiolabelled monoclonal antibody in human tumour with applications to microdosimetry: positron emission tomography studies of iodine-124 labelled 3F8 monoclonal antibody in glioma.

Authors:  F Daghighian; K S Pentlow; S M Larson; M C Graham; G R DiResta; S D Yeh; H Macapinlac; R D Finn; E Arbit; N K Cheung
Journal:  Eur J Nucl Med       Date:  1993-05

3.  High-quality 124I-labelled monoclonal antibodies for use as PET scouting agents prior to 131I-radioimmunotherapy.

Authors:  Iris Verel; Gerard W M Visser; Maria J W D Vosjan; Ronald Finn; Ronald Boellaard; Guus A M S van Dongen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-31       Impact factor: 9.236

Review 4.  Iodine-124: a promising positron emitter for organic PET chemistry.

Authors:  Lena Koehler; Katherine Gagnon; Steve McQuarrie; Frank Wuest
Journal:  Molecules       Date:  2010-04-13       Impact factor: 4.411

5.  (124)I-L19-SIP for immuno-PET imaging of tumour vasculature and guidance of (131)I-L19-SIP radioimmunotherapy.

Authors:  Bernard M Tijink; Lars R Perk; Marianne Budde; Marijke Stigter-van Walsum; Gerard W M Visser; Reina W Kloet; Ludger M Dinkelborg; C René Leemans; Dario Neri; Guus A M S van Dongen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-04       Impact factor: 9.236