Microdialysis based device for continuous extravascular monitoring of blood glucose.

Franz Feichtner1, Roland Schaller, Andreas Fercher, Maria Ratzer, Martin Ellmerer, Johannes Plank, Bernd Krause, Thomas Pieber, Lukas Schaupp.   

Abstract

Glycemic control of intensive care patients can be beneficial for this patient group but the continuous determination of their glucose concentration is challenging. Current continuous glucose monitoring systems based on the measurement of interstitial fluid glucose concentration struggle with sensitivity losses, resulting from biofouling or inflammation reactions. Their use as decision support systems for the therapeutic treatment is moreover hampered by physiological time delays as well as gradients in glucose concentration between plasma and interstitial fluid. To overcome these drawbacks, we developed and clinically evaluated a system based on microdialysis of whole blood. Venous blood is heparinised at the tip of a double lumen catheter and pumped through a membrane based micro-fluidic device where protein-free microdialysate samples are extracted. Glucose recovery as an indicator of long term stability was studied in vitro with heparinised bovine blood and remained highly stable for 72 h. Clinical performance was tested in a clinical trial in eight healthy volunteers undergoing an oral glucose tolerance test. Glucose concentrations of the new system and the reference method correlated at a level of 0.96 and their mean relative difference was 1.9 +/- 11.2%. Clinical evaluation using Clark's Error Grid analysis revealed that the obtained glucose concentrations were accurate and clinically acceptable in 99.6% of all cases. In conclusion, results of the technical and clinical evaluation suggest that the presented device delivers microdialysate samples suitable for accurate and long term stable continuous glucose monitoring in blood.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20101469     DOI: 10.1007/s10544-010-9396-3

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  2 in total

1.  A stepwise approach toward closed-loop blood glucose control for intensive care unit patients: results from a feasibility study in type 1 diabetic subjects using vascular microdialysis with infrared spectrometry and a model predictive control algorithm.

Authors:  Franz Feichtner; Julia K Mader; Roland Schaller; Lukas Schaupp; Martin Ellmerer; Stefan Korsatko; Venkata R Kondepati; H Michael Heise; Malgorzata E Wilinska; Roman Hovorka; Thomas R Pieber
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

Review 2.  Role of microdialysis in pharmacokinetics and pharmacodynamics: current status and future directions.

Authors:  Francine Johansson Azeredo; Teresa Dalla Costa; Hartmut Derendorf
Journal:  Clin Pharmacokinet       Date:  2014-03       Impact factor: 6.447

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.