Literature DB >> 20099898

Binding bacteria to highly branched poly(N-isopropyl acrylamide) modified with vancomycin induces the coil-to-globule transition.

Joanna Shepherd1, Prodip Sarker, Kathryn Swindells, Ian Douglas, Sheila MacNeil, Linda Swanson, Stephen Rimmer.   

Abstract

Binding of highly branched poly(N-isopropylacrylamide) with vancomycin end groups to Staphylococcus aureus induced a coil-to-globule phase transition. The polymers aggregated this gram-positive bacteria (but not gram-negative bacteria) over a wide range of temperatures, but cooling to 24-26 degrees C progressed the polymer-bound bacteria through a globule-to-coil phase transition, after which the bacteria were released.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20099898     DOI: 10.1021/ja907466y

Source DB:  PubMed          Journal:  J Am Chem Soc        ISSN: 0002-7863            Impact factor:   15.419


  8 in total

Review 1.  Temperature-Responsive Smart Nanocarriers for Delivery Of Therapeutic Agents: Applications and Recent Advances.

Authors:  Mahdi Karimi; Parham Sahandi Zangabad; Alireza Ghasemi; Mohammad Amiri; Mohsen Bahrami; Hedieh Malekzad; Hadi Ghahramanzadeh Asl; Zahra Mahdieh; Mahnaz Bozorgomid; Amir Ghasemi; Mohammad Reza Rahmani Taji Boyuk; Michael R Hamblin
Journal:  ACS Appl Mater Interfaces       Date:  2016-08-11       Impact factor: 9.229

2.  pH-responsive non-ionic diblock copolymers: ionization of carboxylic acid end-groups induces an order-order morphological transition.

Authors:  Joseph R Lovett; Nicholas J Warren; Liam P D Ratcliffe; Marzena K Kocik; Steven P Armes
Journal:  Angew Chem Int Ed Engl       Date:  2014-11-21       Impact factor: 15.336

3.  Proteolytic signatures define unique thrombin-derived peptides present in human wound fluid in vivo.

Authors:  Rathi Saravanan; Sunil S Adav; Yeu Khai Choong; Mariena J A van der Plas; Jitka Petrlova; Sven Kjellström; Siu Kwan Sze; Artur Schmidtchen
Journal:  Sci Rep       Date:  2017-10-13       Impact factor: 4.379

4.  Highly-branched poly(N-isopropyl acrylamide) functionalised with pendant Nile red and chain end vancomycin for the detection of Gram-positive bacteria.

Authors:  Thomas Swift; Maria Katsikogianni; Richard Hoskins; Pavintorn Teratarantorn; Ian Douglas; Sheila MacNeil; Stephen Rimmer
Journal:  Acta Biomater       Date:  2019-01-31       Impact factor: 8.947

5.  Synthesis, micellar structures and emission mechanisms of an AIE and DDED-featured fluorescent pH- and thermo-meter.

Authors:  He Guo; Xiaomeng Cheng; Hongping Li; Jun Li; Jinjin Wei; Chongyang Feng
Journal:  RSC Adv       Date:  2020-06-19       Impact factor: 4.036

6.  Development of a novel micro-bead force spectroscopy approach to measure the ability of a thermo-active polymer to remove bacteria from a corneal model.

Authors:  J Pattem; T Swift; S Rimmer; T Holmes; S MacNeil; J Shepherd
Journal:  Sci Rep       Date:  2021-07-01       Impact factor: 4.379

7.  Label-Free Electrochemical Sensor for Rapid Bacterial Pathogen Detection Using Vancomycin-Modified Highly Branched Polymers.

Authors:  Holger Schulze; Harry Wilson; Ines Cara; Steven Carter; Edward N Dyson; Ravikrishnan Elangovan; Stephen Rimmer; Till T Bachmann
Journal:  Sensors (Basel)       Date:  2021-03-08       Impact factor: 3.576

8.  Evaluation of ligand modified poly (N-Isopropyl acrylamide) hydrogel for etiological diagnosis of corneal infection.

Authors:  Nagaveni Shivshetty; Thomas Swift; Abigail Pinnock; David Pownall; Sheila Mac Neil; Ian Douglas; Prashant Garg; Stephen Rimmer
Journal:  Exp Eye Res       Date:  2021-12-03       Impact factor: 3.770

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.